Descargar Imprimir esta página

BS Charger PB-02 Manual De Instrucciones página 6

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 15
POWER SUPPLY
1 - Connect a 12V power supply cable (not supplied) to the 12V 5A output port .
2 - Link the power supply cable to the power socket of your 12V electrical device.
FLASHLIGHT FUNCTION
Press the ON/OFF button for 3 seconds to turn on the LEDs.
Briefly press the button to switch lighting modes (3 available modes: normal, stroboscope and SOS).
TECHNICAL SPECIFICATIONS
Battery capacity
Input
Output
Start current
Peak current
Operation temp
Size
Weight
PROTECTIONS
This device is protected against overload, overheating, overintensity, deep discharge, short circuit and polarity reversal.
TROUBLESHOOTING, CAUSES, SOLUTIONS
TROUBLESHOOTING
No answer while pressing
1
the ON/ OFF button
«Error» light fixed on the
2
smart start cable.
«Error» indicator flashes
+ discontinuous beeper
«Error» indicator flashes
+ continuous sound signal
3
«Error» indicator flashes
+ quick beep
Fixed «Start» light
+ «Error» light fixed.
MAINTENANCE
The warranty covers faulty workmanship for 1 year from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg.: cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
• The proof of purchase (receipt etc ...)
• A description of the fault reported
| www.bs-battery.com
12000mAh (44.4Wh)
5V/2A
• USB1: 5V/2A
• USB2 (Quick Charge): 5V/3A, 9V/2A, 12V/1,5A
• 15V/5A
600A
1200A
-20°C - 60°C
170x80x38 mm
539g
CAUSES
The Power Box is
discharged.
Internal battery voltage
< 11.0V.
Short circuit.
Reverse polarity.
Overheating.
The clamps have been
connected to the battery
for more than 30 seconds.
SOLUTIONS
Charge the product.
Charge the product
Check that the clamps are properly
connected and disconnect/reconnect
the smart start cable.
Check that the clamps are properly
connected and disconnect/reconnect
the smart start cable.
Disconnect the clamps from the battery and the
Power Box and wait 5 minutes then reconnect.
Remove the 2 clamps from the vehicle battery
terminals to protect the unit.
PB-02