TBV-AN BERLIN SERIES
TBV-AN DSP Menu Structure
Fullrange
1-Box
PROCESS
EQ
2-Box
3-Box
User
Low/ High Shelving
Sub menu
Parametric 1 & 2
FULL
XOVER
HP 80
HP 120 Hz
User
XOVER
Freq
Sub Menu
Phase
Auto
FBQ
Single
Learn
Reset
Subwoofer
Function
For single TBV123-AN enclosure. Can be used in LONG or
None
SHORT THROW mode, depending on the application.
Includes equalization to compensate for low frequency
coupling of 2 x TBV123-AN enclosures. Provides matched
sensitivity with nominal flat frequency response under
freefield conditions in SHORT THROW mode. Can also be
used in LONG THROW mode depending on the application.
Includes equalization to compensate for low frequency
coupling of 3 x TBV123-AN enclosures. Provides matched
sensitivity with nominal flat frequency response under
freefield conditions in SHORT THROW mode. Can also be
used in LONG THROW mode depending on the application.
Lets you define your own frequency response setting by
User
entering the corresponding sub-menu.
Low/ High Shelving
Lets you define a low and high shelving filter.
Lets you define a parametric bell-type EQ
Parametric 1 & 2
(Frequency, Qual. and Gain).
Unit is set for default full-range reproduction.
Preset with 80 Hz 24 dB / octave high pass filter.
For use with TBV118L-AN in LP 80 mode
Preset with 120 Hz 24 dB / octave high pass filter.
For use with TBV118L-AN in LP 120 mode
User crossover sub menu for combination with
other subwoofer speaker systems
Preset with 80 Hz 24 dB / octave low pass filter for
LP 80
TBV118L-AN (front-firing). For use with TBV123-AN in
HP 80 mode.
Cardioid preset with 80 Hz 24 dB / octave low pass
filter for TBV118L-AN (rear-firing). For use with
CARDIO
TBV118L-AN (front-firing) in LP 80 mode with 2:1
cabinet ratio (front-firing : rear-firing)
Preset with 120 Hz 24 dB / octave low pass filter for
LP 120
TBV118L-AN (front-firing). For use with TBV123-AN in
HP 120 mode.
Cardioid preset with 120 Hz 24 dB / octave low pass filter
for TBV118L-AN (rear-firing). For use with TBV118L-AN
CARDIO
(front-firing) in LP 120 mode with 2:1 cabinet ratio
(front-firing : rear-firing)
Select the desired crossover frequency:
Freq
• For Fullrange Systems: 55 Hz to 400 Hz.
• For Subwoofer Systems: 50 Hz to 150 Hz.
Phase
Adjust the absolute polarity (0° or 180°).
Automatically sets as many filters as required. Whenever a
Auto
new feedback frequency is discovered, the first filter will be
released to attenuate the new frequency, and so forth.
Activates the FBQ (feedback detection) functionality,
Single
up to 8 feedback filters.
Automatic procedure which searches for feedback
frequencies and locks settings after all 8 filters have
been set.
Learn
WARNING!
Please use ear protection during this procedure.
The feedback signal may approach the system's
maximum level, which may cause hearing damage!
Reset
Resets all filters.
Fullrange
Input
SETUP
INPUT
Volume
Sensitivity
Short Throw
Long Throw
Delay
DELAY
Unit
Limit
LIMITER
Version
SETUP
1. - 20.
LOAD
1. - 20.
SAVE
Save Preset
Sub Menu
Contrast
SETUP
Screen
Lock
Sub Menu
Warning
23
Quick Start Guide
Subwoofer
Function
Lets you choose the audio input source. Choose between
Input
Local (analogue input) or ULTRANET (e.g., P16 monitoring
system or M32 audio via ULTRANET).
Adjusts the input gain. With ULTRANET digital inputs over
Volume
a range from + 10 dB to - 30 dB. With analogue input from
0 dB to - ∞ dB.
Adjusts input sensitivity for maximum output. When using
Sensitivity
an analogue source +4 dBu for normal operation, +14 dBu
for high level input.
Nominal-flat low and high frequency response under
freefield conditions. Suitable for 1-3 TBV123-AN enclosures
when used for short throw applications including:
distributed front fill, stereo infill, under-balcony fill and
stacked, tripod-mounted or pole-mounted systems for short
throw front-of-house or sidefill stage monitoring.
For medium- to long-throw applications. Suitable for
suspended arrays consisting of 1-3 TBV123-AN enclosures.
High-frequency shelving pre-emphasis compensates for air
absorption over typical throw distances and is combined
with low frequency shelving to provide an enhanced
LF contour.
Adjusts the amount of delay
Delay
(max 300msec = 103 m or 338 feet).
Unit
Selects between msec, meters and feet.
Adjust the limiter threshold for the input signal
(from OFF up to -30 dB). This threshold adjustment
Limit
allows you to set a max output power which is below the
loudspeaker system's rated max output.
Version
Displays the installed firmware version.
To load a specific preset, turn the encoder to select the
desired preset's number, and then press either the ENTER
1. - 20.
button or the encoder. When asked to confirm press the
encoder again or EXIT to abort.
To save a preset choose the respective preset slot and
1. - 20.
press ENTER or the encoder.
Name the preset by choosing the characters with
Save Preset
the encoder and pressing to confirm each character.
When finished, press the ENTER button to save the preset.
Contrast
Adjust LCD panel contrast. The default contrast value is 15.
ON: LCD screen saver (default) turns on automatically
Screen
after approx. 2 minutes.
OFF : LCD turns off automatically after approx. 5 minutes.
Lock the device and create a password by choosing the
password characters with the encoder and pressing to
confirm each character. When finished press the ENTER
Lock
button. Unlock the device by entering the password or
connecting the unit via USB to a PC running proprietary
remote software. The software does not require a password.
In case of overheating, an alert appears on the LCD screen,
Warning
and the amplifier will shut down until the unit cools