EN
3.3 MONTAGEM DA
MANGUEIRA DE ASPIRAÇÃO
(FIG.E)
1. Insert the hose (11) connector into the
connector (14) and turn clockwise;
2. Check that the hose is securely
fastened;
To remove the suction hose:
3. Turn the hose connector
counterclockwise and remove the hose.
3.4 MOUNTING OF SUCTION
PIPE AND SUCTION FITTINGS
(FIG. F)
1. Insert one of the suction tubes into
(13) the other;
2. Insert the lower end of the assembly
into the floor accessory (17, 21);
3.5 CONNECTION OF THE PIPE
SUCTION HOSE
AND ACCESSORIES (FIG. G)
If you want to use the floor accessory:
1. Insert the suction fitting handle /
connector (12) into the suction tube
(13);
For the remaining suction fittings:
2. Insert the suction fitting handle /
connector (12) into the fitting nozzle
(17, 21, 22, 23);
4. OPERATING
INSTRUCTIONS
Do not use the vacuum cleaner for
more than 4 hours, including rest
breaks. Make sure the vacuum cleaner
is switched off regularly, to let the
engine cool down (every 15 min turn off
for 1 min). Otherwise, the motor may be
damaged.
Never use the vacuum cleaner to
vacuum:
� Hazardous Dusts for Health
� Hot or red hot materials such as
cigarettes, matches or hot ashes;
� Flammable or combustible liquids,
such as gasoline, solvents, acids or
lyes;
� Combustible or explosive dust, such
as magnesium powders;
� Sharp objects.
Never use the vacuum cleaner if the
suction power becomes too weak. If
this happens, check that the filter bag is
full and check the cleaning status of the
filters (see maintenance instructions).
Also check for blockage or clogging in
the suction hose, tubing or fittings.
Avoid breathing dusts and materials
that may slow the flow of air and block
or clog the suction fittings.
Do not use the vacuum cleaner if it does
not operate normally. If the problem
persists, send the vacuum cleaner to
the service center.
4.1 VACUUM START / STOP
(FIG. H)
1. Unplug the power cord (18) and plug
it into the wall outlet.
2. Attach the suction fitting of liquid or
dust and solids (17, 21), according to
the waste to be drawn;
3. Set one of the "ON / OFF" buttons
to the (I) (10) position. If the suction
power is not sufficient, set the other
"ON / OFF" button to (I) to increase
suction power and flow rate;
To switch off the vacuum cleaner:
4. Set the "ON / OFF" buttons to (0)
and disconnect the power cord;
Always switch off the vacuum cleaner
before unplugging the power cord.
5. Wrap the power cord
4.2 - ASPIRATION OF DUST
AND SOLID (FIG. I)
1. Attach the dust and solids suction
fitting to the floor (17) and select the
position of the brush according to the
type of floor to be vacuumed;
(a) For carpets and wood flooring
press the selection button down.
(b) For ceramic floors, pull the
selection button upwards.button
upwards.
2. Keep the bag (26) filter placed
inside the vacuum cleaner.
4.3 - ASPIRATION OF LIQUIDS
(FIG. J)
1. Attach the liquid suction attachment
(21);
2. Unscrew the latches (6) remove the
head from the vacuum cleaner (7);
3. Remove the bag (26) filter from
inside the vacuum cleaner.
4. Insert the head of the vacuum
cleaner and switch on the vacuum
cleaner.
Always remove the bag filter when
sucking liquids.
4.4 - CLEANING THE WASTE
CONTAINER
Whenever
the
waste
becomes full, stop the vacuum cleaner
and remove the waste from the
container.
When inhaling dust or solid waste
(Fig. K):
1. Stop the vacuum cleaner;
2. Unscrew the latches (6) and remove
the head from the vacuum cleaner (7);
3. Remove the bag filter (26);
container
29