Descargar Imprimir esta página

Deltafox DC-HPW 1511 Traducción Del Manual De Instrucciones Original página 28

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 116
2. Unlock the switch lever (20), see
"Locking the high-pressure gun".
3. Switch off the On/off switch (10) when
you are not using the device for pro-
longed periods.
Cleaning with the foam nozzle
Requirements of the cleaning agent:
This device has been designed to be
used with a neutral cleaning agent
based on biodegradable anionic sur-
factants.
Use of other cleaning agents or chemi-
cal substances can negatively impact
the safety of the device and can cause
damage.
You can buy cleaning agents in our
online shop.
Filling the cleaning tank:
Fill the cleaning agent tank with cleaning
agent to the upper marking.
The cleaning agent is automatically suc-
tioned through the foam nozzle (15) in low
pressure mode.
Bleeding
If there is air remaining in the device,
please proceed as follows:
Bleed the garden hose:
1. Turn off the tap.
2. Remove the quick connector (22) on
the water connection (9).
3. Turn on the tap.
Let the water flow out of the garden hose
until there are no more bubbles in the
water.
4. Turn off the tap.
5. Using the quick connector (22), con-
nect the garden hose to the water con-
nection (9) on the device.
Bleed the device:
1. Turn on the device with the On/off
switch (10).
2. Wait until the motor has built up the
necessary pressure and stops.
3. Turn off the device with the On/off
switch (10).
4. Press the switch lever (20) of the high-
pressure gun (1) until the pressure has
released.
5. Repeat the process a few times until
there is no more air in the device.
Ending the operation
Release pressure from the device:
The nozzles (15/16/17), the
lance (12) and the high-pressure
hose (3) can only be removed
after the pressure has been re-
leased from the device.
1. Release the switch lever (20) of the
high-pressure gun (1).
2. Turn off the pressure washer with the
On/off switch (10).
3. Unplug the mains plug.
4. Turn off the tap.
5. Press the switch lever (20) of the high-
pressure gun for 30 seconds. The re-
maining pressure in the system will be
released.
6. Release the switch lever (20) of the
high-pressure gun (1).
7. Unlock the switch lever (20) of the
high-pressure gun, see "Locking the
high-pressure gun".
8. Disconnect the device from the water
supply.
GB
27

Publicidad

loading