Installing Fan to
the Outlet Box
WHEN MOUNTING THE FAN ON A SLOPED CEIL-
ING, THE STANDARD BALL/DOWNROD MOUNT-
ING METHOD MUST BE USED. MAKE SURE THE
MOUNTING PLATE SLOTS ARE ON THE LOWER
SIDE BY SLIDING THE MOUNTING PLATE FROM
THE TOP DOWN.
1. Pass the 120-volt supply wires through the
center hole in the ceiling mounting plate as
shown in Figure 7.
2. Install the ceiling mounting plate on the out-
let box by sliding the mounting plate over
the two screws provided with the outlet
box (Figure 7).When using close-to-ceiling
mounting, it is important that the mount-
ing plate be level. If necessary, use leveling
washers (not included) between the mount-
ing plate and the outlet box. Note that the
flat side of the mounting plate is toward the
outlet box.
3. Securely tighten the two mounting screws.
4. Carefully lift the fan assembly up to the ceil-
ing mounting plate and hang the fan on the
hook provided by utilizing one of the holes
at the outer rim of the ceiling canopy (Fig-
ure 11). If using standard mounting, seat the
hanger ball in the mounting plate socket.
Make sure the tab on the mounting plate
socket is properly seated in the groove in
the hanger ball.
6.
All manuals and user guides at all-guides.com
THE HOOK AS SHOWN IN FIGURE 11 IS ONLY
TO BALANCE FAN WHILE ATTACHING WIRING.
FAILURE TO HANG AS SHOWN IN FIGURE 11
MAY RESULT IN HOOK BREAKING, CAUSING
THE FAN TO FALL. HOOK MUST PASS FROM
INSIDE TO OUTSIDE OF CANOPY
WHEN USING THE STANDARD BALL/DOWNROD
MOUNTING, THE TAB IN THE RING AT THE BOT-
TOM OF THE MOUNTING PLATE MUST REST IN
THE GROOVE OF THE HANGER BALL. FAILURE
TO PROPERLY SEAT THE TAB IN THE GROOVE
COULD CAUSE DAMAGE TO WIRING.