4.4) ERRORS:
these appear during operation, combined with a beep and fl ashing LED Worklights,
to notify the operator of procedural or operational errors.
Message
Error description
The pressure release button (5) was
pressed before the control parameters
ERROR
were reached (Force/Pressure).
Interruption of the signal from the
NTC
NTC temperature probe of the battery.
FAULT
Abnormal power consumption of the
motor for more than 3 seconds.
001
The tool stops.
Output voltage of the pressure trans-
002
mitter is out of the pre-set range.
Failure to reach the set pressure within
003
30 seconds of continuous operation
of the machine.
Overcharging of the battery with
protection tripping.
004
The tool stops.
Errors are displayed for about 30 seconds before being reset, but will display repeatedly in
the event of permanent anomalies.
5. CONNECTION TO COMPUTER (Smartool technology)
The memory card integrated in the tool records operating datafor transfer via the USB cable supplied.
To view and manage this data, go to www.cembre.com and register in the dedicated area, then
download the free CEMBRE software CEM_SWBT01.
Keeping the Firmware of the tool updated, via free of charge download from here, will optimise
the tool's performance.
6. RETURN TO CEMBRE FOR OVERHAUL
In the case of a breakdown contact our Area Agent who will advise you on the problem and give
you the necessary instructions on how to dispatch the tool to our nearest service Centre; if possible,
attach a copy of the Test Certifi cate supplied by CEMBRE together with the tool or fi ll in and attach
the form available in the "ASSISTANCE" section of the CEMBRE website.
Solution
Repeat the work cycle and wait for the
motor to stop automatically.
Replace the battery.
If the problem persists, please contact
CEMBRE.
Wait for the display to turn off (60 sec.)
or remove and re-insert the battery,
then re-start the tool.
If the error occurs frequently, contact
CEMBRE.
Repeat the work cycle; if the error
occurs frequently, contact CEMBRE.
Repeat the work cycle; if the error
occurs frequently, contact CEMBRE.
Wait for the display to turn off (60 sec.)
or remove and re-insert the battery,
then re-start the tool.
If the error occurs frequently, contact
CEMBRE.