Do not apply pressure to or stab at the touch button, a light touch using a bare fi nger is
suffi cient. The command pulse is sent when the fi nger releases the button.
2.8) Battery status
The battery is equipped with LED indicators that indicate the remaining battery life at any time
by pressing the adjacent button (P) (Ref. to Fig. 5):
4 LEDs illuminated: fully charged
2 LEDs illuminated: 50 % capacity
1 LED flashing: minimum charge, replace the battery.
With the battery inserted into the tool, the remaining
battery life can also be checked on the display, via touch
button selection (Ref. to § 4).
The screen shown alongside indicates that the battery voltage has
dropped below a minimum safety threshold; under these conditions
the tool will not start,and it is necessary to recharge or replace the bat
tery. The approximate time to fully recharge a battery is about 100 miutes.
2.9) Using the battery charger
Carefully follow the instructions in the battery charger user manual.
3. MAINTENANCE
The tool is robust, completely sealed, and requires very little daily maintenance. Compliance with
the following points, should help to maintain its optimum performance:
3.1) Thorough cleaning
Dust, sand and dirt are a danger for any hydraulic device.
Every day, after use, the tool must be wiped with a clean cloth taking care to remove any residue,
especially close to pivots and moveable parts.
Do not use hydrocarbons to clean the rubber parts.
3.2) Storage case
(Ref. to Fig. 7)
When not in use, the tool should be stored and transported in the plastic case, to prevent damage.
The case, type VAL-P39, is suitable for storing the tool, the accessories and up to 8 die sets and pre-
prepared compression connectors.
VAL-P39: Size 520x432x126 mm (20.5x17.0x5.0 inches). Weight 2,6 kg (5.7 lbs).
9
min.
max.
BATTERY
BATTERY
BATTERY