7
Specifications:
Type
Voltage type
Protection rating
Engine performance
Security of the supply line
Max. Flow rate
(SAE 30 free outlet)
Suction height
Max discharge pressure
(depending on oil viscosity)
Volume
Measurements
L x W x H (mm
Weight
(pump unit without accessories)
Pumped Liquids EP 200-DS, EP 300-DS, EP 400-DS:
Oils based on mineral oil and biodegradable oils.
Fluids including Hazard Class A3 can be supported.
Viscous media of Hazard Classes A1 and A2 can not be supported.
If media not listed here are used, please clarify this with our technical department.
If oils (particularly used oils) with high levels of abrasive particles (metal dust, sanding dust, etc.) are
pumped, then a fine filter must be retrofitted into the suction line of the pump.
Not suitable for water, chemicals and corrosive media
8
Disposal
After termination of use the device is to be disposed of in an environmentally
friendly manner in accordance with applicable statutory provisions.
Your contribution to protection of the environment:
The applicable regulations for the registration, installation and operation of equipment for
handling of substances hazardous to water are to be strictly observed by the operator (such as,
e.g., Federal Water Act, German Ordinance on Exposure to Substances Hazardous to Waters
and Technical Rules and Regulations for Flammable Liquids).
12
/ Benzstr. 16-24 / 63165 Mühlheim a. Main / Tel:+49(0)6108-906-0 / Fax:+49(0)6108-906-120
GmbH & Co. KG
MATO
EP 200-DS
230V / 50 Hz
0,75 KW
16 A
ca. 11 l/min
ca. 22 l/min
self-priming
16 bar
Approx. 67 dB(A)
275
270
205
260
x
x
12 kg
Operating manual
EP 200-DS / EP 300-DS / EP 400-DS
EP 300-DS
EP 400-DS
IP 55
0,37 kW
0,75 kW
10 A
ca. 22 l/min
up to 2,5m
8 bar
16 bar
260
205
290
x
x
x
10,5 kg
12,5 kg
16 A
270
205
x