equipment DESCRIPTION
5 . 2 p o w e r s u p p l y
The power supply of the Lusso shampoo unit has been created for an electric cable
directly connected to the control unit, equipped with a plug for the socket. Cable and plug
are supplied with the shampoo unit. The power supply must be sized for the following
characteristics – 100/220-240 V ~ 50-60 Hz, monophased. Furthermore, the electrical
system must comply with the laws and regulations in force at the place of use, and must
be equipped with a differential switch that ensures people's protection against indirect
electrical contact. The power supply line of the Lusso shampoo unit must be protected
against overload and short circuit. Plug the machine into an easily accessible socket,
checking that the voltage (V) of the network corresponds to the plate on the machine.
• Avoid use of extension cords, adapters and multiple sockets; when possible insert the
plug directly in the socket.
• Keep the power cord away from areas of passage in order to avoid crushing,
interference or obstacles to movement.
• Keep the power cord away from heat sources or hot surfaces. To avoid dangerous
electrical shocks, use a correctly installed socket.
We ask that you request support from your trusted installation company.
5 . 3 e l e c t r i c A L c o m p o n e n t s
1.
Power supply
7333
22
Equipment description
2.
3.
Control-box
Massage system
3885
3888
equipment DESCRIPTION
4.
Legrest actuator
Massage panel control
3954
5 . 4 h y d r a u l i c c i r c u i t
The Lusso shampoo unit has hydraulic fittings to connect to the salon's hot and cold
water system. It is also equipped with a drainage pipe that allows connection to the
drainage system of the salon where the shampoo unit is placed.
Technical plumbing characteristics:
• Pressure testing = 15 bar
• Cold water supply = blue pointer to the right
• Hot water supply = red pointer to the right
Operating limits by UNI 10234 (EN 817):
• Pressure = Min. 0.5 bar Max. 10 bar
• Temperature = Max. 90°C
Operating limits recommended by UNI 10234 (EN 817) for the correct functioning of the
tap:
• Pressure = Min. 1 bar Max. 5 bar
• Temperature = Max 65°C
Warnings:
• It is necessary to thoroughly wash and rinse all piping systems to avoid damage to the
taps caused by residue present in the tubes
• For pressure over 5 bar, it is recommended to install a pressure reducer
• It is recommended that you install a centralised filter for dirty water or impurities
For further details, see section 7 regarding installation of the shampoo unit.
5.
6.
Legrest panel control
3953
3886
Equipment description
EN
23