PRESIDENT MC KINLEY Manual Del Usuario página 49

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2. Press the CH knob (5) button to confirm. The radio automatically
TX
switches to
mode without pressing the PTT switch (12) and
calibration begins. Calibration time is 5 minutes maximum. A
countdown is done in the display.
3. Adjust the antenna.
-
The beep* is continuous when the SWR value is 1. 0 . The space
between the beeps becomes larger and larger as the SWR value
moves away from1. 0 .
-
The volume of the beep is adjustable with the VOL button (1).
-
The display shows the SWR value, for example 2. 5 .
4. Press the PTT switch (12) to
*Check that the beep volume is set to a suitable level.
See ADJUSTMENT OF SWR page 41.
9) ECHO ADJUSTMENT
Press the CH knob (5) for 3 seconds to
1. Turn the rotary CH knob (5) or use the UP/DN buttons (13) on the
select
microphone to
the ECHO SET menu.
2. Press the CH knob (5) button to confirm. The LEVEL of the ECHO
flashes in the display.
3. Turn the rotary CH knob (5) or use the UP/DN buttons (13) on the
microphone to
set
the level value from1 to 32 (default level:13).
4. Press the CH knob (5) button again to
The second parameter, DELAY, flashes.
5. Use the rotary CH knob (5) or the UP/DN buttons (13) on the mi-
crophone to
set
the delay value from1 to 32 (default value:16).
6. Press the CH knob (5) again to
stops flashing. a) Start again at point 1 to
b) Press the PTT switch (12) to
7. If no key is pressed, the unit
appears from the display.
See § ECHO page 45.
10) TONE
This function allows to change the
+5
Press the CH knob (5) for 3 seconds to
exit
the SWR CALIBRATION.
enter
MENU.
appears.
validate
the level value.
confirm
the delay value. The delay
set
another function or
exit
MENU.
exits
MENU after 10 seconds.
RX
TONE. 11 steps from -5 to
enter
MENU.
appears.
1. Turn the rotary CH knob (5) or use the UP/DN buttons (13) on the
microphone to
select
2. Press the CH knob (5) to confirm. The tone value flashes in the
display.
3. Turn the rotary CH knob (5) or use the UP/DN buttons (13) on the
microphone to
change
4a. Short press the CH knob (5) again to
and
stay
in the MENU.
4b. Long press (1s) the CH knob (5) again to
exit
in the MENU.
value and
5. If no key is pressed, the unit
appears from the display.
Tone default value is : 0.
11) EMERGENCY CHANNEL 1
Press the CH knob (5) for 3 seconds to
1. Turn the rotary CH knob (5) or use the UP/DN buttons (13) on the
select
microphone to
2. Press the CH knob (5) button to confirm. The first parameter, the
modulation mode, flashes in the display.
3. Turn the rotary CH knob (5) or use the UP/DN buttons (13) on the
microphone to
set
1: AM, FM, USB, LSB or FM UK (in U configuration only).
4. Press CH knob (5) again to confirm. The modulation mode stops
flashing, the second parameter, the channel, flashes in the display.
5. Use the rotary CH knob (5) or use the UP/DN buttons (13) on the
select
microphone to
6. Press CH knob (5) again to
point 1 to
set
another function or b) Press the PTT switch (12) to
exit
MENU.
dis-
7. If no key is pressed, the unit
disappears from the display.
Emergency channel 1 default is 9 in AM.
See § EMERGENCY CHANNELS page 44.
12) EMERGENCY CHANNEL 2
Press the CH knob (5) for 3 seconds to
49
the TONE menu.
the value of the tone.
validate
the selected value
validate
disappears from the display.
exits
MENU after 10 seconds.
enter
MENU.
the EMG 1 menu.
the modulation mode for emergency channel
the emergency channel 1.
confirm
the channel. a) Start again at
exits
the MENU after 10 seconds.
enter
MENU.
the selected
dis-
appears.
appears.

Publicidad

Tabla de contenido
loading

Tabla de contenido