Descargar Imprimir esta página

DeWalt DCL045 Traducido De Las Instrucciones Originales página 21

Ocultar thumbs Ver también para DCL045:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 27
Batteries
Cat #
V
Ah
DC
DCB546
18/54 6.0/2.0
DCB547
18/54 9.0/3.0
DCB548
18/54 12.0/4.0
DCB181
18
1.5
DCB182
18
4.0
DCB183/B/G
18
2.0
DCB184/B/G
18
5.0
DCB185
18
1.3
DCB187
18
3.0
DCB189
18
4.0
DCB122
12
2.0
DCB124/G
12
3.0
DCB125
12
1.3
DCB126/G
12
5.0
DCB127
12
2.0
*Date code 201811475B or later
**Date code 201536 or later
Residual Risks
In spite of the application of the relevant safety regulations
and the implementation of safety devices, certain residual risks
cannot be avoided. These are:
Impairment of hearing.
Risk of personal injury due to flying particles.
Risk of burns due to accessories becoming hot
during operation.
Risk of personal injury due to prolonged use.
SAVE THESE INSTRUCTIONS
Chargers
D
WALT chargers require no adjustment and are designed to be
e
as easy as possible to operate.
Electrical Safety
The electric motor has been designed for one voltage only.
Always check that the battery pack voltage corresponds to the
voltage on the rating plate. Also make sure that the voltage of
your charger corresponds to that of your mains.
i
Your D
WALT charger is double insulated in
e
accordance with EN60335; therefore no earth wire
is required.
If the supply cord is damaged, it must be replaced only by
D
WALT or an authorised service organisation.
e
Mains Plug Replacement
(U.K. & Ireland Only)
If a new mains plug needs to be fitted:
Safely dispose of the old plug.
Weight
DCB104 DCB107 DCB110 DCB112 DCB113 DCB115 DCB116
kg
1.05
60
270
X
1.46
75*
420
X
1.44
120
540
X
0.35
22
70
X
0.61
60/40**
185
X
0.40
30
90
X
0.62
75/50**
240
X
0.35
22
60
X
0.54
45
140
X
0.54
60
185
X
0.20
30
90
90
0.25
45
140
140
0.20
22
60
60
0.22
75
240
240
0.20
30
90
90
Chargers/Charge Times (Minutes)
170
140
90
80
270
220
135*
110*
350
300
180
150
45
35
22
22
120
100
60
60/45** 60/40** 60/40**
60
50
30
30
150
120
75
75/60** 75/50** 75/50**
40
30
22
22
90
70
45
45
120
100
60
60
60
50
30
30
90
70
45
45
40
30
22
22
150
120
75
75
60
50
30
30
Connect the brown lead to the live terminal in the plug.
Connect the blue lead to the neutral terminal.

WARNING: No connection is to be made to the
earth terminal.
Follow the fitting instructions supplied with good quality plugs.
Recommended fuse: 3 A.
Using an Extension Cable
An extension cord should not be used unless absolutely
necessary. Use an approved extension cable suitable for
the power input of your charger (see Technical Data). The
minimum conductor size is 1 mm
is 30 m.
When using a cable reel, always unwind the cable completely.
Important Safety Instructions for All
Battery Chargers
SAVE THESE INSTRUCTIONS: This manual contains important
safety and operating instructions for compatible battery
chargers (refer to Technical Data).
Before using charger, read all instructions and cautionary
markings on charger, battery pack, and product using
battery pack.

WARNING: Shock hazard. Do not allow any liquid to get
inside charger. Electric shock may result.

WARNING: We recommend the use of a residual current
device with a residual current rating of 30mA or less.

CAUTION: Burn hazard. To reduce the risk of injury,
charge only D
e
batteries may burst causing personal injury and damage.

CAUTION: Children should be supervised to ensure that
they do not play with the appliance.
DCB117
DCB118 DCB132 DCB119
40
60
60
75*
135*
80
120
180
22
22
30
30
22
22
45
45
60
60
X
X
X
X
X
X
X
X
X
X
; the maximum length
2
WALT rechargeable batteries. Other types of
EngLIsh
90
X
X
X
22
45
60
120
30
60
75
150
22
X
45
90
60
120
30
60
45
90
22
40
75
150
30
60
19

Publicidad

loading