Storage and Preparation for Future Use
1. Drain and clean the spa by following the "Drainage" and "Spa
Cleaning" sections.
2. Refer to the instructions to deflate air bladder.
3. Make sure all the spa components and accessories are thoroughly
clean and dry before storage. Air-dry the spa tub in the mild sun for
an hour before folding.
4. Fold the spa tub loosely and avoid any sharp corners to prevent
damage or leakage to the spa liner.
5. Prepare new additional cartridges for next time use.
6. Store the spa and accessories in a dry, temperature-controlled
environment, between 0°C and 40°C (32°F - 104°F). We recommend
storing the spa with desiccant.
7. The original packaging is recommended for storage.
8. After long-term storage, fill the spa with clean water and sanitizer,
and turn on the FILTER for at least 1 hour before use.
DISPOSAL AND ENVIRONMENTAL PROTECTION
This mark indicates that the product should not be disposed of with other household waste. To prevent
possible harm to the environment or human health from uncontrolled waste disposal, products should be
recycled responsibly to promote the sustainable reuse of material resources. Information on disposal can be
obtained from your local authorities.
To return your used device, please use the return and collection systems or contact the retailer where the
product was purchased for environmentally safe recycling.
ERROR CODE CHART
LED READING
The Signal wire is loose
- - - / 888 / EEP
Communication failed
Water temperature is below 0°C (32°F)
or exceeds 50°C (122°F)
F0
Temperature sensor failure
F1 immediately shows after pressing FILTER,
HEATING or UVC
F1
F1 shows 15s after pressing FILTER, HEATING
or UVC
TROUBLESHOOTING
CAUSE
16
SOLUTION
Contact local MSpa Service Center
Contact local MSpa Service Center
Change the water
Contact local MSpa Service Center
Clean the parts and tubes that the water
goes through
1. Add more water to the minimum line
2. Clean the parts and tubes that water
goes through
3. Contact local MSpa Service Center