Descargar Imprimir esta página

Blaupunkt 5RG64361 Instrucciones De Uso página 34

Ocultar thumbs Ver también para 5RG64361:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 104
ELECTRICAL CONNECTION
This appliance should only be installed and connected to the electrical system by a qualified
electrician.
Protection against live parts must be ensured after installation.
The required connection data can be found on the labels on the hob casing near the connection
box.
The connection to the mains must be made via an earthed plug or via an all-pole separator with
a contact opening of at least 3 mm.
The electric circuit must be separated from the mains by means of suitable devices, e.g: circuit
breakers, fuses or contactors.
If the appliance is not equipped with an accessible plug, separators must be installed in the
system in accordance with the installation instructions.
The input cable must be laid so that it does not touch any of the hot parts of the hob.
Caution!
This appliance may only be connected to a mains supply with 230 V/400 V ~ 50/60 Hz.
Always connect the earth cable.
Please observe the wiring diagram.
The connection box is located on the back of the hob casing. To open the lid, use a medium-sized
screwdriver. Insert it into the slots and open the cover.
Mains
230V~50/60Hz
400V~ 50/60Hz
* calculated with the simultaneity factor according to the standard EN 60
335-2-6
Connection
1 phase + N
2 phases + N
Cable diameter
3 x 2.5 mm²
4 x 2.5 mm²
16
Protection
Cable
H 05 VV - F
25 A *
H 05 RR - F
H 05 VV - F
16 A *
H 05 RR - F
class

Publicidad

loading

Este manual también es adecuado para:

5rg74351