Error codes
Error code
The main board cannot connect to the control
EC/E16
panel.
E0
Electrical circuit failure.
E1
Protection against empty vessels.
E2
Low voltage protection.
E3
High voltage protection.
E4
Circuit of the temperature sensor is open.
E4
Short circuit on the temperature sensor.
E7
Open circuit of the IGBT sensor.
E7
Short circuit on the IGBT sensor.
E8
Overheating of the temperature sensor.
E9
Overheating of the IGBT sensor.
DISPOSAL OF USED UNITS.
At the end of its useful life, this product should not be disposed of with normal household waste but should
be taken to a collection point for the recycling of electrical and electronic equipment. This is indicated by
the symbol on the product, operating instructions, or packaging. The materials used in this appliance are
recyclable according to their marking. By reusing, recycling, or applying other forms of use of waste
machines, you make a significant contribution to the protection of our environment.
Your local administration will provide you with information about the appropriate disposal point for used
appliances.
Error
Analysis
Check the connection of the wires between
the main board and the display control board.
Check the coil.
Is the pan placed on the induction hob? Is the
vessel compatible with the hob?
Check the voltage value.
Check the voltage value.
Check if the temperature sensor is damaged or
disconnected.
Check if the temperature sensor is damaged in
its insulation or if its metal wire is exposed.
Check if the socket is damaged.
Check if the IGBT sensor is damaged or
disconnected.
Check if the IGBT sensor has insulation
damage or if its metal wire is exposed.
Check if the socket is damaged.
Check if the fans under the coil are damaged
or if there is poor heat dissipation.
Check if the fans on the main board are
damaged or if the air intake is blocked,
resulting in poor heat dissipation.