Summary
Description
Weight
size(LxWxH)
Cooling
Welder Type
European Standards
Mains voltage
Grid frequency
Wire roll weight
Wire roll diameter
Efficiency
Power Factor
Welding Current Range (MIG Mode)
Welding Current Range (STICK Mode)
Welding Current Range (WIG Mode)
Effective Input Current
Maximum Input Current
Three Phase Generator Requirement
Duty cycle, 40°C, 10 min(MIG)
Duty cycle, 40°C, 10 min(MMA)
Duty cycle, 40°C, 10 min(TIG)
Open Circuit Voltage
Protection Class
Insulation Class
NOTE
Note 1: The Effective Input Current should be used for the determination of cable size & supply
requirements.
Note 2: Generator Requirements at the Maximum Output Duty Cycle.
Note 3: Motor start fuses or thermal circuit breakers are recommended for this application. Check local
requirements for your situation in this regard.
Due to variations that can occur in manufactured products, claimed performance, voltages, ratings, all
capacities, measurements, dimensions and weights quoted are approximate only. Achievable capacities
and ratings in use and operation will depend upon correct installation, use, applications, maintenance
and service.
51
MIG SERIES EQUIPMENT
MIG295
13kg
493x222x375
Fan Cooled
Multi Process Inverter
Power Source
EN 60974-1 / IEC 60974-1
3 x 400 Volt ±15%
50/60Hz
15kg
0.6/0.8/1.0
80%
0.8
30-295 A
30-250 A
10-280 A
11 A
24.8A
15KVA
295A@ 60%28.8V
228A@ 100%25.4V
250A@ 60%30V
194A@ 100%27.8V
280A@ 60%21.2V
217A@ 100%18.7V
60V DC
IP23
H
MIG SERIES EQUIPMENT
2.4 Duty cycle
The rated duty cycle of a Welding Power Source is a statement of the time it may be operated
at its rated welding current output without exceeding the temperature limits of the insulation
of the component parts. To explain the 10 minute duty cycle period the following example
is used. Suppose a Welding Power Source is designed to operate at a 40% duty cycle,
185 amperes at 23 volts. This means that it has been designed and built to provide the
rated amperage (185A) for 4 minutes, i.e. arc welding time, out of every 10 minute period
(40% of 10 minutes is 4 minutes). During the other 6 minutes of the 10 minute period the
Welding Power Source must idle and be allowed to cool.
(MMA)
(TIG)
(MIG)
Safe
Operating
Region
0
20
40
60
80
Welding Current (amps)
2.5 Packaged Items
MIG145 / MIG165
◆200 A electrode holder with 3m
◆300 A earth clamp with 3m
◆2m Gas connection hose 5x8
(MIG145 not configured Gas connection
hose)
◆Operating Manual
MIG295
◆3m MB-24AK MIG Gun
◆300 A electrode holder with 3m
◆300 A earth clamp with 3m
Summary
100
120
140
160
180
200
MIG185 / MIG205 / MIG225 / MIG255
◆3m MB-15AK MIG Gun
◆200 A electrode holder with 3m (MIG255
Configure 300 Amps / 3m)
◆300 A earth clamp with 3m
◆2m Gas connection hose 5x8
◆Operating Manual
◆2m Gas connection hose 5x8
◆Operating Manual
52