Instruction manual
WARNING
Specific information regarding appliances with R 290
refrigerant gas.
• Thoroughly read all of the warnings.
• When defrosting and cleaning the appliance , do
not use any tools other than those recommended
by the manufacturing company.
• The appliance must be placed in an area without
any continuously sources of ignition (for example:
open flames , gas or electrical appliances in
operation).
• Do not puncture and do not burn.
• Appliance shall be installed, operated and stored
in a room with a floor area larger than X m2. (X=4
for 5000Btu/h, 7000Btu/h, 8000Btu/h; X=7.7 for
9000Btu/h, 10000Btu/h, 10500Btu/h)
• This appliance contains Y g (see rating label back of
unit ) of R290 refrigerant gas.
• R290 is a refrigerant gas that complies with the
European directives on the environment. Do not
puncture any part of the refrigerant circuit.
• If the appliance is installed, operated or stored in
a nonventilated area, the room must be designed
to prevent to the accumulation of refrigerant leaks
resulting in a risk of fire or explosion due to ignition
of the refrigerant caused by electric heaters, stoves,
or other sources of ignition.
• The appliance must be stored in such a way as to
prevent mechanical failure.
4
All manuals and user guides at all-guides.com
• Individuals who operate or work on the refrigerant
circuit must have the appropriate certification
issued by an accredited organization that ensures
competence in handling refrigerants according to
a specific evaluation recognized by associations in
the industry.
• Repairs must be performed based on the
recommendation from the manufacturing
company. Maintenance and repairs that require
the assistance of other qualified personnel must be
performed under the supervision of an individual
specified in the use of flammable refrigerants.
REFRIGERANT
(CE) N 842/2006: This air conditioner contains the refrigerant R290. The
amount of refrigerant is less than 1kg, and is in a closed cooling circuit.
The coolant does have zero ozone depletion potential, but is a so-called
greenhouse gases under the Kyoto Protocol and may thus contribute to
global warming, if it is released to the atmosphere. Therefore only trained
technicians with refrigerant certificate make a filling or emptying. Your air
conditioner does not have be refilled with refrigerant if used properly and
has an undamaged coolant circuit. GWP: R290: 3