Descargar Imprimir esta página

Tristar AC-5474 Manual De Usuario página 8

Ocultar thumbs Ver también para AC-5474:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 35
Instruction manual
Twist both ends of the exhaust hose into the square fixing clip and the
flat fixing clip.
Insert the square fixing clip into openings at back of the air conditioner.
Put the other end of the exhaust hose to the near windowsill.
Window Slider Kit Installation
The installation manner of window slider kit is mostly in "horizontal"
and "vertical", No much difference in actual process.
8
All manuals and user guides at all-guides.com
CLEANING MAINTENANCE
Before cleaning, be sure to disconnect the unit from any electric supply
outlet.
First clean the surface with a neutral detergent and wet cloth, and then
wipe it with a dry cloth.
Do not use gasoline or other chemicals to clean the unit.
Do not wash the unit directly.
If the conditioner is damaged, please contact the dealer or repair shop.
Air Filter
If the air filter becomes clogged with dust/dirt, the air filter should be
cleaned once every two weeks.
Open the air inlet grille and take off air filter.
Clean the air filter with neural detergent in lukewarm(40°C(and dry it
up in the shade.
Putting the air filter into the inlet grille, replace the components as
they were.
TROUBLE SHOOTING
Troubles
The unit does not start
when pressing power
button
The unit doesn't cool
enough
Possible Causes
Suggested Remedies
Water full indicator lamp blinks,
Dump the water out of the
and water tank is full.
water tank.
Room temperature is higher
Reset the temperature
than the setting temperature.
Reset the temperature
(Electric heating mode)
Room temperature is lower
than the setting temperature.
(Cooling mode)
The doors or windows are
Make sure all the windows
not closed.
and doors are closed.
There are heat sources inside
Remove the heat sources if
the room.
possible
Exhaust air hose is not
Connect or clean the exhaust
connected or blocked.
air hose.
Temperature setting is too high.
Reset the temperature
Air inlet is blocked.
Clean the air inlet.

Publicidad

loading

Este manual también es adecuado para:

Ac-5477Ac-5527prAc-5529Ac-5531