2.1
Electrical connections
Neutral 230 Vac 1
Non usato 2
Phase 230 Vac 3
Lamp
M1 Com 6
M1 Open 7
M1 Close 8
M2 Com 9
M2 Open 10
M2 Close 11
CLS M2 12
OLS M2 13
CLS M1 14
OLS M1 15
Photo A 16
START 17
24Vac 18
24Vac / 12Vac 19
12Vac elec. lock 20
STOP 21
PEDESTRIAN 22
Photo B 23
Common 1 - 24
Antenna + 25
LIGHT o Lamp. 26
LIGHT o Lamp. 27
PHOTOTEST 28
PHOTOTEST 29
12 Vac 30
+ 24 Vdc 31
- 24 Vdc / Comm. 32
All manuals and user guides at all-guides.com
230 Vac power supply 50Hz Neutral
Non utilizzato
230Vac power supply 50Hz Phase
4
Output for lamps (with flashing electronic card) or Courtesy light.
Maximum power of the lamp with 40.
5
Output for the connection of motor 2 COMMON pole
Output for the connection of motor 1 pole OPEN
Output for the connection motor 1 pole CLOSE
Output for the connection of motor 2 COMMON pole
Output for the connection of motor 2 pole OPEN
Output for the connection motor 2 pole CLOSE
Input close limit switch motor 2
Input Open limit switch motor 2
Input close limit switch motor 1
Input Open limit switch motor 1
Input photo-beam A activated when closing (see par. 2.3)
Input bi-stable START
Output 24Vac
Output for electrical lock 12 Vac 50Hz 1A
Output for electrical lock 12 Vac 50Hz 1A
Input STOP
Input bi-stable command for partial opening
Input photocell B activated when closing and opening
Common for all input: services, safeties, coaxial cables
Input for antenna
Contact for LIGHT (for lamps without electronic card)
Contact for LIGHT (for lamps without electronic card)
Isolated contact for interlock or test
Isolated contact for interlock or test
Output 12 Vac
Output + 24 Vdc
Output - 24 Vdc / Common, services and safeties
-7-