Connection of LIMIT SwITCHES
You can see the connection of both limit switches, in this control unit they can be connected separatelly.
So you can use only the OLS or CLS.
12 13 14 15 16 17 18 19 20 21 22 23 24 25
Limit Switches MOT 1
CLOSE
Limit Switches MOT 2
CLOSE
5.9
Connection of a command OPEN: START / PARTIAL OPENING
12 13 14 15 16 17 18 19 20 21 22 23 24 25
If more devices are available they should be connected in serial. Connect a timer in the terminal board no.
16 and 22 to programm the opening time of the gate. The timer contact shoudl be no. (normally open) and it
should be closed when the gate is opening. If the it is available the connection in the terminal board no.16,
connect it in serial
All manuals and user guides at all-guides.com
OPEN
OPEN
S 11
S 12
S 13
S 14
!
If the OLS or CLS are not used,
bring S11, S12, S13 and S14
on "0"
PARTIAL
OPENINg
-17-
Technical manual
Input OLS1
1 - Activated
0 - Deactivated
Input CLS1
1 - Activated
0 - Deactivated
Input OLS2
1 - Activated
0 - Deactivated
Input CLS2
1 - Activated
0 - Deactivated
The connection of the PAR-
TIAL OPENING can be done
with every button or a normal-
ly open contact.
The connection of a START
command can be done with
every button or normally clo-
se contact N.O.