5.10
STOP connection
17 18 19 20 21 22 23 24 25
S 15
5.11
Connection of the ANTENNA
If a wire is used as antenna, cut it to 17 cm for a
frequency of 433MHz and connect it to terminal.
23 24 25
onnection of the motor with ELECTRO-MAgNETICAL BLOCk
5.13
C
If a electrical-magnetic block is available, bring S26 into 1 and make as follow:
S 26
If you use this function for all time the motor is wor-
king, the output for the electrical lock is powered,
this release the brake and the correct functon of
the motor.
All manuals and user guides at all-guides.com
STOP Input
1 - Activated
0 - Deactivated
Work function
RELEASE
of the BRAkE
1 - Activated
0 - Deactivated
Button: stop until a new command.
Switch: it keep the automation closed until
a new command.
The connection of the safety devices is due to a
button or a normally closed contact. More devi-
ces should be connected in parallel.
5.12
Power of the ACCESSORIES
17
18
19
Terminal board 18-19
Tension: 24 Vac
17 18 19 20 21 22 23 24 25
-18-
Technical manual
!
If the input STOP
is not connected,
bring S15 into 0
20
21
Terminal board 31-32
Tension: 24 Vdc
Terminal board 19-30
Tension: 12 Vac
MOT
MOTOR