TROUBLESHOOTING
Problem
Machine does not run
Machine has little or no
suction
TECHNICAL SPECIFICATIONS
Voltage/Frequency
Current
Max Airflow
Water lift
Tank Capacity
Standard paper bag capacity
Optional microfiber bag capacity
Power cord length
Weight
Sound pressure level [dBA]
Protection
Cause
ON/OFF switch is off
Machine not plugged to wall outlet
Faulty on/off switch
Faulty power cord
Faulty vacuum motor
Hose is clogged
Holes in hose
Intake is clogged
Head is not securely latched
Worn gasket which is leaking air
Tank or bag is full
The float valve has shut off the
suction due to high level of liquids
inside the tank
Drain hose cap is loose (V-WD-24
model)
V-WD-9
120 V, 60 Hz
8.5 A
200 m
/h; 117,72 cfm
3
2530 mmH
35 L; 9.3 Gal
21 L; 5.6 Gal
12.0 L; 3.2 Gal
8.5 m; 27.89 ft
9.7 kg / 21,4 lb
72,5 dBA
IPX4
Solution
Turn switch to on
Plug power cord to wall outlet
Contact service center
Contact service center
Contact service center
Clear hose
Replace hose
Remove
obstruction
Close both latches down securely
Inspect all gaskets, replace if
necessary
Empty tank or bag.
Turn off the machine, empty the
tank and check the float valve.
Tighten cap (V-WD-24 model)
V-WD-24
120 V, 60 Hz
8.5 A
200 m
O; 99.6"
2530 mm H
2
90 L; 23.8 Gal
37 L; 9.8 Gal
36 L; 9.5 Gal
0.4+12 m; 1.3+39.4 ft
19 kg / 41.9 lb
70,0 dBA
IPX4
TENNANT V-WD-9 / V-WD-24
EN
hose
and
clear
/h; 117,72 cfm
3
O; 99.6"
2
11