3.4.4 CAN-Bus
battery chargers have two terminals made for connectors Molex Microfit 3.0, 6 circuits (reference 43045-
0600).
Documentation n° 1336205REG_CAN (hardware and software specification) is available upon request.
Protocol
CAN-Bus protocol can be chosen with the programming field 3 (see 3.3.4).
Power Supply
The power supply of the CAN-Bus can either be carried out by another
equipment or by the charger itself.
To generate the power supply, simply move the two jumpers JP1 and JP2 to
position 1-2.
Communication
To allow communication between multiple devices, each entity must have a
unique identifier (ID). This identifier must be selected using the 4 micro
switches (1,2,3,4).
Within the same CAN network, 4 sub-networks can be defined (A, B, C, D).
Thus, only the 4 entities of the sub-networks can communicate with each other.
Switches settings
1
2
0
0
1
0
0
1
1
0
0
0
Factory settings
1
0
0
1
1
1
0
0
1
0
0
1
1
1
0
0
1
0
0
1
1
1
ID
3
4
0
0
0
0
0
1
0
0
2
0
0
3
1
0
4
1
0
5
1
0
6
1
0
7
0
1
8
0
1
9
0
1
10
0
1
11
1
1
12
1
1
13
1
1
14
1
1
15
Master/Slave
function
Master A
Master B
Master C
Master D
Slave A1
Slave B1
Slave C1
Slave D1
Slave A2
Slave B2
Slave C2
Slave D2
Slave A3
Slave B3
Slave C3
Slave D3
Jumpers JP1 et JP2
Dip switches :
(1, 2, 3, 4)
Sub-network
A
B
C
D
A
B
C
D
A
B
C
D
A
B
C
D