Descargar Imprimir esta página

Cristec YPOWER+ 12V/16A Manual De Usuario página 54

Ocultar thumbs Ver también para YPOWER+ 12V/16A:

Publicidad

Idiomas disponibles

Idiomas disponibles

12V-40A, 12V-60A, 24V20A, 24V 30A
Part Number
Model
recommended battery bank*
Input
Voltage
Frequency
Input current consumption 230/115VAC
Recommended power for a generator
Power factor
Efficiency
Input fuses
Output
Number of battery banks
Nominal current (+/-7%) / Rated Power
Charging curve
Battery type
Boost voltage
Floating voltage
Regulation tolerance before output
Mosfet splitter and fuse
Peak to peak ripple and noise
Automotive output fuse mounted in
series in minus pole -BAT
Environment
Cooling
Sound level
Operating temperature at 230VAC
Storage temperature
Relative humidity
Casing
Material
Dimensions (length, height, depth) /
Weight
Fixing center distance
Fixing screw (wall)
Protection factor
PCB protection
Standards
CE declaration of conformity
CE / EMC MARK
CE / Security MARK
Protections
Communication
Options
*Recommended battery capacity for lead type batteries, ratio C/10. Consult us for lithium batteries capacity
YPO12-40STPL/(OEPL)
YPO12-60STPL/(OEPL)
12V-40A
300-500Ah
2.7/5.6A
700W
4 separate positive terminals : +BAT E, +BAT 1 et +BAT 2 +BAT3 (integrated Mosfet splitter) / 1 -BAT
Each bank can be used individually and delivers the rated current
40A/570W
IU or IUoU through internal push-button, Bluetooth or CAN-Bus
Lead sealed as factory setting - Gel, AGM, calcium lead, LiFePO4, DC power-supply mode, etc.
14.4VDC for lead sealed battery (factory setting)
13.8VDC for lead sealed battery (factory setting)
3 x 30A/32V
(F400, F401, F402)
(F400, F401, F402, F403)
From -20°C to +60°C, derating above 60°C. Outside the operating ranges -20°C +65°C automatic shutdown.
Casing comprises 3 parts: Aluminium sink frame / Thermoplastic body / Aluminium clasp
- Against transient input overvoltage by varistor (out of warranty)
- Against output polarity inversions by fuse (replaceable automotive type)
- Against short-circuits and output overloads
- Against abnormal overheating by charger cut-off (automatic restart)
CANBUS / Bluetooth as standard (optional on OE version)
Temperature probe / Bluetooth dongle (OE versions)
YPO24-20STPL/(OEPL)
12V-60A
500-700Ah
from 90 to 265VAC single-phase automatic
from 47 to 65Hz automatic
4.4/8.7A
1050W
1
Greater than 90%
T15A/250V – 6.3x32 (F101)
negative terminals
60A/855W
(Boost, Absorption, Floating and Refresh)
Specific request on demand
28.8VDC for lead sealed battery (factory setting)
27,6VDC for lead sealed battery (factory setting)
< 2% (at rated conditions)
< 2% (at rated conditions)
4 x 30A/32V
fanless
0dB SPL
Automatic restart within operating ranges.
From -20°C to +70°C
up to 70% (95% without condensation)
289 x 195 x 106 mm / 3.74kg
272 x 170 mm
4 x M5 round head screws
IP22
Water-repellent varnish (marine environment)
Available on request
EN61204-3
EN60335-2-29, ISO8846
YPO24-30STPL/(OEPL)
24V-20A
200-300h
300-500Ah
2.9/5.9A
700W
20A/570W
30A/855W
1 x 30A/32V
2 x 30A/32V
(F400)
(F400, F401)
24V-30A
4.5/8.8A
1050W
53

Publicidad

loading