AXIL-230V
Opening mechanical stop
AXIL-120V
Built-in trigger capacitor
Opening mechanical stop
AXIL-FC
Built-in trigger capacitor
Opening electrical limit switch
Max. leaf lenght
Max. leaf weight
Power supply
Idling current
Full load current
Maximum Power
Capacitor
Max travel
Operating speed
Maximum thrust
Working temperature
Protection
Working cycle
Motor weight
- cable 4 x 0,75 mm
AXIL actuator
- cable 3 x 1,5 mm
Blinker
cable 2 x 1,5 mm
cable RG-58
Aerial
cable 3 x 0,5 mm
Key or digital selector
- optical type
Safety edge (EN 12978)
- resistive type
TECHNICAL DATA
AXIL-230V
m
2,8
Kg
300
Vac - Hz
230 - 50
A
0,8
A
1,1
W
230
µF
6,3
mm
350
m/s
0,016
N
1700
°C
-30 ÷ +55
IP
44
%
35
Kg
7,5
INSTALLATION LAYOUT
2
(120V/230V)
2
(24V)
2
2
AXIL-ECD
AXIL-24V
AXIL-120V
AXIL-24V
2,8
2,8
300
300
120 - 60
24 Vdc
1,7
1,0
2,2
8
240
200
14
-
350
350
0,018
0,02 ÷ 0,012
1700
1700
-30 ÷ +55
-30 ÷ +55
44
44
30
60
7,5
7,5
Internal photocells
External photocells
Control unit
8
Opening mechanical stop
Built-in trigger capacitor
Encoder
Opening mechanical stop
Encoder
cable 4 x 0,5 mm
2
(RX)
cable 2 x 0,5 mm
2
(TX)
cable 4 x 0,5 mm
2
(RX)
cable 2 x 0,5 mm
2
(TX)
cable 3 x 1,5 mm
2