Panorama Nova RP
Full face masks with plug-in connector

Instructions for Use

For your safety
Strictly follow the instructions for use. Any use of the full face mask
requires full understanding and strict observation of these instructions.
The mask may only be used for the purposes specified here.
Maintenance: Note the instructions in the section entitled "Mainten-
ance intervals". Only original Dräger parts may be used for
maintenance. We recommend that a service contract be signed with
your local Dräger Service.
Liability for proper function or damage: Liability for the proper func-
tion of the full face mask is irrevocably transferred to the owner or
operator to the extent that the mask has been serviced or repaired by
personnel not employed or authorized by Dräger Service or if it has
been used in a manner not conforming to its intended use. Dräger
cannot be held responsible for damage caused by non-compliance with
the recommendations given above. The warranty and liability provisions
of the terms of sale and delivery of Dräger are likewise not modified by
the recommendations given above.
Dräger Safety AG & Co. KGaA
Markings
These Instructions for Use apply for masks with the following type
markings:
Panorama Nova –
EPDM / PC / RP
Panorama Nova –
EPDM / PC / RP / T
Panorama Nova –
SI
Panorama Nova –
SI
The marking is visible from the outside: Panorama Nova and EPDM or
SI on the faceblank. PC on the visor. RP and T (telephone) on the
facepiece connector.
What's what
1 Facepiece connector
6
2 Clip
7
3 Inner mask
8
4 Visor
9
5 Clamping frame
10 Button
6
5
4
3
2
9
1
10
Description / intended use
The above full face masks are respiratory masks with plug-in connector
(quick-release connector) for closed-circuit breathing apparatus. The
masks meet the requirements of EN 136 Cl. 3 and bear the CE mark.
They protect the face and eyes against corrosive media. Spectacle
frames can be fitted for people with glasses. The masks marked "T"
include an adapter for connection of the headset R 28 495 which has
been tested and approved for use in mines. A simple wiper ensures
good visibility. Temperature when used –30 °C to 120 °C. Only use
certified respiratory protective devices!
1) Note the corresponding Instructions for Use.
2) Henkel-Ecolab, D-40589 Düsseldorf, Germany.
Note the corresponding Instructions for Use.
4
/ PC / RP
/ PC / RP / T
Front strap
Head straps
Softbody
Faceblank
7
8
Use
For masks with visor wiper: Soak the wiper with the demisting agent
1)
"klar-pilot" fluid
. It must not be actuated when dry.
Hold the full face mask ready: Undo the
straps as far as possible. Hang the neckband
(if fitted) round your neck and button it into the
front strap.
Put on the closed-circuit breathing
1)
apparatus
and press the plug-in connector
into the facepiece connector until it engages.
Put on the mask: Beards and sideburns in
this area will cause leaks and persons with
such facial hair should therefore not use this mask. Spectacle frames in
the sealing area will also cause leaks; special spectacle frames for
masks should be used.
Unbutton the strap and place chin in recess.
Fit straps round head and pull them back until
the front strap rests smoothly on the face.
Position the mask.
1 Tighten the neck straps uniformly.
2 Tighten the temple straps uniformly.
3 Tighten the front strap as well if the head is
fairly small.
Check for leaks: Tightly compress both breathing hoses and breathe in
until a vacuum is produced. Briefly hold your breath: the vacuum must
be maintained. If it is not, the straps must be tightened further. The leak
test must be repeated twice. The mask may only be used if perfectly
tight!
Wiper: If the visor mists over, it can be cleared by wiping. The wiper is
actuated via a lever on the outside of the visor. The wiper must then be
returned to its basic position in the middle of the visor.
Headset: Adjust the earphone so that it fits over the ear. Connect the
headset to the telephone line via connector or pricker and check the
functions "Speaking and hearing".
Extreme operating conditions
At low temperatures: Apply "klar-pilot" anti-misting gel to the inside of
1 )
the visor to prevent misting
.
At high temperatures: If the visor is damaged, leave the danger zone
immediately.
At alternating high and low temperatures: In the case of visors
marked PC, the visor coating may come loose in places. After wiping
away the blistered particles, you can continue using the mask until the
end of the mission. Then replace the visor.
On exposure to chemicals: Certain substances, such as H
phosgene, may be absorbed and subsequently released by the mask
material, especially silicone.
In explosion-hazard areas: Treat the mask with antistatic spray or use
a water screen.
After use
Disconnect the closed-circuit breathing apparatus: Press the button
and simultaneously draw the plug-in connector out of the facepiece
connector.
Remove mask: Slide your index finger under
the ends of the neck straps, press the clamps
forwards with your thumbs and evenly pull the
mask over your head and off your face.
Cleaning, disinfecting, drying
Only use approved cleaning products and disinfectants.
Cleaning: The mask must be cleaned whenever it has been used.
Position the wiper in the middle of the visor. Headset: unscrew
microphone, remove headphone and earpiece. Only the earpiece
(rubber part) may be cleaned and disinfected, all other parts must
remain dry.
Do not use solvents, such as acetone, alcohol, etc. to clean rubber and
silicone parts. The mask must be thoroughly rinsed in lukewarm water
containing a little all-purpose Sekusept Cleaner
and a cloth. Rinse thoroughly under running water.
Disinfection: The mask must be disinfected whenever it has been used.
Immerse the mask in the disinfectant. Only use approved disinfectants,
2)
such as Incidur
(order no. 79 04 072). High doses and long exposure
times can damage the mask! Rinse thoroughly under running water.
Mechanical cleaning and disinfecting with Eltra:
Order no. 79 04 074 – follow Instructions 90 21 380.
Drying: Leave the mask to dry in a drying cabinet or in air. Maximum
temperature 60 °C. Keep away from direct sunlight.
3
2
1
S, and
2
2)
(order no. 79 04 071)