5
Pre-oparation
NOTICE
TIP:
The generator can be used with the rated output load at standard atmospheric
conditions.
"Standard atmospheric conditions "; Ambient temperature 25c.Barometric
pressure 100kPa; Relative humidity 30%
The output of the generator varies due to change temperature,altitude (lower air
pressure at higher altitude) and humidity.
The output of the generator is reduced when the temperature, the humidity and
the altitude are higher than standard atmospheric conditions.
Additionally, the load must be reduced when using in confined areas,as generator
cooling is affected.
STARTING THE ENGINE
Never operate the engine in a closed area or it may
cause unconsciousness and death within a short
time. Operate the engine in a well ventilated
area.The generator has been shipped without engine
oil.Do not start the engine till fill with the sufficient
engine oil.
Turn the air vent knob to"ON"○
Turn the 3 in 1 switch to"CHOCK"○
a.lgnition circuit is switched on.
b.Fuel is switched on.
c.Chock is switched off.
TIP: The choke is not required to
start a warm engine.Push the choke knob in
to the position"ON".
18
Inverter Generator Owner's Manual
Operation
.
2
3