indicator (green) will go OFF. Stop both engines and investigate the problem.Determine
if the cause is a short circuit in a connected appliance or an overload, correct the
problem and restart the generator.
AC PARALLEL OPERATION
Before connection an appliance to either generator, make sure that it is in good working
order and that its electrical rating does not exceed that of the receptacle.
During parallel operation, the EsC switch should be in the same position on both
generators.
1.Connect the parallel operation cable between the generator to either an generator or
companion generator following the instructions
supplied with the cable kit.
2.Start the engines and make sure the output indicator (green) on each generator
comes on.
3.Plug an appliance into the AC receptacle.4.Turn on the appliance.
AC Parallel Operation Applications
TIP:
Make sure that it is in good working order. A faulty appliance or power cord can
create a potential for electrical shock.
If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly,
turn if off immediately. Disconnect the appliance and determine whether the
problem is the appliance, and determine
whether the problem is the appliance or the rated load capacity of the generator
has been exceeded.
Make sure that the combined electrical rating of the tools or appliance do not
exceed that of the generator. Never exceed the maximum maybe used for no more
than 30 minutes.
Never connect different generator models.
Don't remove the parallel operation cable when the generator operation.