2.6
SOLAR KIT (code 8105100)
This kit, supplied with the boiler, can be used
to connect the boiler to a solar system and
B
C
F
2.6. 1
Configuration with solar kit
to compare the temperature of the water
supplied by the solar accumulator with the
one set on the water potentiometer.
This means that the boiler switches on only
B
A
D
ø 18
SOLAR MANIFOLD
SOLAR KIT
SOLAR
ACCUMULATOR
TEHRMOSTATIC
MIXING
VALVE
if the temperature of the solar boiler is
below the one set on the boiler.
To connect the kit to the boiler, follow the
instructions provided in fig. 6.
KEY
A Hot water supply tube connected
to the solar boiler
B Gasket
C Thermostatic mixing valve
D NTC temperature control probe
E Cable for CN4 connector
F 1/2" female water supply tube
NOTES:
– Connect the temperature control probe
(D) to the hot water supply tube (A) ,
which is in turn connected to the solar
accumulator.
E
– Unwind the probe connection cable (E)
placed next to the heating fittings.
– Connect the faston connectors of cable
(E) to the probe (D).
WATER EXHAUST
WATER SUPPLY
NTC PROBE
IT
ES
PT
GB
Fig. 6
Fig. 6/a
77