Exhaust air hose
Depending on the mode setting, the exhaust air hose must be mounted or dismantled:
Cooling mode, automatic mode: with exhaust hose.
Fan mode, dehumidification mode: without exhaust air hose.
Wall installation (parts: L, M, N, O)
Fig. 1
Place the wall and exhaust hose adapters on one side of the exhaust air hose. Connect the
exhaust hose adapter to the air outlet of the device.
Fig. 2
Use the wall connector as a template to transfer the drilling pattern to the wall. Drill holes with a
suitable power tool. Before starting drilling, make sure that there are no pipes in the wall around
the holes. Free the holes from drilling dust and attach the wall connector with the enclosed
screws and dowels. Connect the wall adapter to the wall connector.
Notes:
The exhaust air hose can be pulled apart or pushed together; however, keep the hose length as
short as possible for optimal performance. Do not extend the exhaust hose, avoid overturning.
If you are not using the product for an extended period of time, refer to the decommissioning
instructions in the appropriate section.
Drainage hose
Fig. 3
The drainage hose is required to drain water from the upper drain.
Slide the drainage hose as far as possible onto the upper drain.
Insert the other end of the drainage hose into a suitable drain ora nearby-drain.
Notes
Depending on the set operating mode, the water is directed outwards orcollected in an internal
tank.
Empty the device accordingly.
Always cover the processes when they are not needed.
If you are not using the device for an extended period of time, refer to the decommissioning
instructions in the appropriate section.