▶ Check the appliance's supply cord at regular intervals and have it replaced by a qualified specialist if
found to be damaged. If the machine's supply cord is damaged it must be replaced with a specially
prepared and approved supply cord available from Hilti Customer Service. Check extension cords at
regular intervals and replace them if found to be damaged. Do not touch the supply cord or extension
cord if it is damaged while working. Disconnect the supply cord plug from the power outlet. Damaged
supply cords or extension cords present a risk of electric shock.
3
Description
3.1
Product overview
3.2
Intended use
The vacuum pump is designed to create a vacuum for securing a drill stand with a vacuum base plate and for
use in combination with vacuum holding jigs such as are used, for example, with Hilti diamond core drilling
machines (core bits up to max. 250 mm diameter).
•
The vacuum pump is designed exclusively for intaking air. Intaking other gases or liquids is prohibited.
•
The product must not be used in an explosive environment.
3.3
Items supplied
Vacuum pump, operating instructions
Other system products approved for use with this product can be found at your local Hilti Store or at:
www.hilti.group
4
Technical data
4.1
Product properties
Weight
Dimensions (L x W x H)
Power input
Maximum volumetric flow rate
Minimum relative volume flow rate
Water separator capacity
Protection class
Protection class
Voltage
Rated current input
Frequency
*416185*
1
416185
Pressure gauge
@
On/off switch
;
Grip
=
Supply cord hook
%
Supply cord
&
Hose
(
Air vents
)
Water separator
+
Ball float
§
Cage
/
9.0 kg
383 mm x 154 mm x 282 mm
450 W
6 m³/h
700 mbar
0.5 ℓ
Protection class I (earthed)
IP 54
230 V
2.1 A
50 Hz
English
9