Descargar Imprimir esta página

Klein Tools CL445 Manual De Instrucciones página 10

Publicidad

Idiomas disponibles

Idiomas disponibles

ENGLISH
AC CURRENT (LESS THAN 600A)
AC Current is measured by pressing the clamp trigger
the clamp and placing it around a current-carrying wire. When
measuring, care should be taken to ensure that the clamp is
completely closed with trigger
passes perpendicularly through the center of the clamp in line
with the arrow markings
NOTE: Current measurement can be made by clamping around single
conductors, but not cables containing both live and neutral wires. In this
case a line splitter is required, Klein Cat. No. 69409 is recommended.
To measure current:
1. Rotate the Function Selector switch
to the A~ setting.
2. Place clamp around wire. The current
measurement will be shown in the display.
Disconnect test leads when
measuring with the clamp.
AC/DC VOLTAGE (LESS THAN 600V DC OR 750V AC)
1. Insert RED test lead into V µA jack
into COM jack
V
setting for AC or DC measurements. The meter defaults to
AC measurement. To measure DC, press the "SELECT" button
to toggle between AC and DC modes. The AC or DC icon on
12
the LCD indicates which mode is selected. Note "AC" or "DC" on
the display.
Black lead
10
OPERATING INSTRUCTIONS
10
.
11
, and rotate function selector switch
4
Red lead
fully released, and that the wire
2
, and BLACK test lead
5
to open
10
to the
2

Publicidad