Parameter
Parameter
Code
Content
Select opening
of electronic
C23
expansion valve
in Heating or
Standby mode
Temperature
C24
Unit
Set lowest
cooling
*
C25
temperature
limit
Set highest
heating
C26
temperature
limit
Set to display
C27
0.5°C
Select
Parameters
00/01/02/FF
01
00/01
00
Celsius:
30°C - 17°C
(20°C)
Celsius:
Fahrenheit:
17 °C(20°C)
86°F - 62°F
Fahrenheit:
(68°F)
62°F
Celsius:
30°C - 17°C
Celsius:
30 °C
Fahrenheit:
Fahrenheit:
86°F - 62°F
86 °F
00/01
00
Default
Remarks
Value
Parameter
Value
Represents
00: Celsius
01: Fahrenheit
Fresh air processing unit:30°C/86°F~
13°C/55°F.
AHU controller box(outlet air temperature
control):30°C/86°F~10°C/°F.
Only available for the wired controller itself.
(68°F)
Only available for the wired controller itself.
00: Show 1 ° C
01: Show 0.5°C
31
00
01
02
FF
Based on the dial
72 96
00
switches in the
main PCB of the
indoor unit