IP addressing external entrance panel UT8020
The procedure below describes how to assign an IP address that is compatible with your system to the UT8020
external entrance panel:
1. Open the software ViP Manager version 2.13.0 or later (downloadable from the website pro.comelitgroup.com).
2. From Options [a] / Local connections [b], select the network interface [c] to use (if several cards are
installed, select the one to which the network cable has been connected).
3. The audio/video modules are configured by default in Auto IP; press Auto IP [d] to assign an IP address to
your PC (the IP Address, Subnet Mask and Default Gateway fields will be completed automatically by the
software).
Warning! If the IP addressing configuration has already been changed, the local connection
should be configured on the basis of the programming carried out. If the system has been
connected to a server with DHCP protocol active, select DHCP enable. If a static address has been
assigned to the UT8020 module, complete the IP address and Subnet mask fields to assign the same
class of IP address as the module to your PC.
4. Confirm by pressing OK [e].
5. Click Scan system [f] to start searching for devices.
During the system scan...
AN IP COMPATIBLE
WITH THE SYSTEM
WILL BE ASSIGNED
TO THE PC
SYSTEM
SCAN
Installer PC
6. Select module UT8020 [g].
7. In Addressing / IP address [h], select DHCP IP address mode and select Use default gateway.
8. Select Write page [i].
» The device will restart with the IP address provided by the network.
g
f
b
h
a
c
d
e
i
23