4. LCD Display Operating Instructions
4.2 Description of adjustment parameters
Key Operation Instructions: To enter the setup menu and exit the setup menu, press the "SET" key. After entering the settings
menu, the parameter number [00] will blink. At this point, press the "UP" and "DOWN" keys to select the parameter code to be set.
Then press the "ENT" key to enter the parameter edit state, the parameter value flashes at this time, adjust the parameter value
through the "UP" and "DOWN" buttons, and finally press the "ENT" key to complete the parameter edit and return to the parameter
select state.
Note: In parallel mode, all machines will synchronize the host machine's configuration parameters (the machine with "P" on the screen) before starting.
After starting the machine, the parameters set for any machine will be synchronized with other machines in the system.
NO.
Element
00
Exit
Work Priority Mode
01
02
Output Frequency
03
AC Input Voltage Range
04
Battery to mains
05
Battery-powered network
Configuration Options
[00] ESC.
[01] SUN
[01] UTI Default
[01] UEN
[02] 50,0
[02] 60
[03] LPA
[03] Default UPS
[04] 46.0 Default value
[05] 56.0V Predetermined
77
Description
Exit the setup menu
PV priority mode, when there is no PV input orhe
battery is less than the value set by the parameter
[04], it switches to the network.
Network priority mode, switch to battery inverter only
when there is no network input.
Inverter priority mode, switch to network only when
battery is low voltage or below parameter setting value
[04]; switch to battery discharge only when battery is
fully charged or above parameter setting value [05].
Avoid self-adaptation. When there is current, it adapts
automatically to the frequency when it is first turned on:
when there is no current, the output frequency can be
adjusted through this menu. The 230V machine defaults
to 50HZ, and the 120V machine defaults to GOHZ.
230V machine wide range mains voltage input range
90~280V.
120V main machine input range 90~140V.
230V Narrow Range Main Network Voltage Input
Machine Range 170~280V
120V main machine input range 90~140V.
When the parameter [01] =SBU, the battery voltage is
lower than the set value, the output is changed from
inverter to network and the adjustment range is 44 V ~
52V.
When the parameter [01] =SBU, the battery voltage is
higher than the set value, the output is switched from
the network to the inverter, the adjustment range is
48V~60V.