10. POST-INSTALLATION & MAINTENANCE
The ArrowMAX
HOME is designed to give years of trouble-free use. However,
TM
there are some simple tasks should be performed to ensure continued operation.
a. Check monthly that none of the connectors are leaking.
b. Replace the in-line filter(s) after winterization or as per the instructions on the
filter label.
c. Replace the reactor LEDs at the end of their lifetime. Refer to the replacement
manual for detailed instructions.
Note: Precautions are to be taken when replacing UV-LEDs. The replacement must be
carried out by a licensed plumber and/or licensed technician, and replacement by the user is
not allowed.
Note: The small quartz windows inside the
temperatures to encourage mineral build-up (scaling) as with UV lamp systems. As a result,
no significant scaling or loss of performance due to scaling the conventional time is
expected. This also eliminates the maintenance needs for cleaning.
10.1 Water Treatment System
Use the following steps to fully flush the lines throughout the entire home after a
new installation, replacement of UV-LED heads, or after the loss of power.
a. Remove the filter cartridge from the Pre-filter and fill it with 1-2 cups of household
bleach (most are 5.25% chlorine). Replace the sump and slowly turn on the water
supply.
b. Turn on the water and run the water until bleach can be smelled to ensure the
lines are flushed. Repeat this step for all faucets, toilets, shower heads,
appliances, outdoor taps, etc. Once complete, wait at least 30 minutes before
continuing to the next step.
c. Put the filter cartridge back into the Pre-filter and flush the chlorine solution by
opening all faucets in the home until chlorine can no longer be detected.