If the unit is to be installed on a floor slab, its sufficient load-bearing capacity must be checked. In general, it
is recommended that a building expert be consulted for an assessment when installing the machine on floor
ceilings.
The machine is only to be installed and used inside closed rooms. It does not have appropriate safety equipment
(e.g. IP protection, galvanized design) for outdoor use.
Temperature
Sea level
Humidity
Safety area
Permissible operating temperatures
Maximum permitted humidity
Altitude above sea level
Necessary supply line
Power connection & grounding cable (see
device (socket and plug) or a fixed connection.
2.5
Fastening
Warning
General as well as local regulations must be observed when fixing the device.
Therefore, these steps should only be carried out by a trained specialist.
The machine is to be set up and fastened on sufficiently solid ground, if necessary, according to the minimum
requirements of the specifications in the foundation plan.
The machine must be fastened at the intended points with suitable fastening material, if specified.
® Copyright ATH-Heinl GmbH & Co. KG / All rights reserved / Misprints and technical changes reserved
80
"Electrical
Release date: 05.04.2023 / Product manufacturer ATH-Heinl GmbH & Co. KG
5 - 50°C
< 1500m
50% at 40°C - 90% at 20°C
Min. 1 m
10-40 °C
≤80% at 30 °C
≤2000m
See
"Electrical connection"
connection") is to be installed in the form of a plug-in