32.
PREPARATIONS AND DETERGENT – RINSE AID DISPENSERS
If the machine is connected to a water softener and/or reverse osmosis unit contact the detergent supplier for a specific
product. Peristaltic dispensers (rinse aid and detergent) require period maintenance. The tube inside the rinse aid
dispenser must be subjected to period maintenance (at least 1 or 2 times a year). All models in the range are equipped as
standard with both pumps, peristaltic pump for the detergent and peristaltic rinse aid pump.
detergent dispenser pump: Pump supplies approx. 0.9 g/s of detergent. The operating time of the dispensers can
be changed according to the instructions provided in the following paragraph. Insert the supplied tube in the detergent
container.
rinse aid dispenser pump: Pump supplies approx. 0.1 g/s of rinse aid. The operating time of the dispensers can be
changed according to the instructions provided in the following paragraph. Insert the supplied tube in the rinse aid
container.
MANUAL ACTIVATION
During the initial start-up phase of the machine or when replacing the containers, the dispensers must be activated
manually so that the tubes are filled up, in the first case, or to eliminate the air in the second case.
Detergent dispenser
press the buttons shown below in the figure at the same time
until "De Te" appears on the display. The dispenser
is filled for approx. 60 s each time it is pressed, repeat the
operation multiple times if necessary.
Rinse aid dispenser
press the buttons shown below in the figure at the same time
until "Ri Ns" appears on the display. The dispenser
is filled for approx. 60 s each time it is pressed, repeat the
operation multiple times if necessary.
33.
DISPENSER ADJUSTMENT DURING THE CYCLES
The adjustment of dispensers during the cycles and tank filling can be carried out with the switched off. To modify the
dispenser parameters, access the main parameter menu, following and paying attention to the sequence of the
instructions listed below.
With machine switched off, Press the buttons shown below at the
same time for 6 seconds, one of the general parameters from the list
will appear on the display
press the parameter scrolling buttons, "III" back button, forward
button "Drain cycle" until the desired parameter is shown on the
display
pag. 23
Disconnected boiler sensor. Please check the sensor connections.
Damaged boiler sensor. Please check the sensor functioning.
Rinsing is not carried out at the set temperature. Boiler temperature is not reached after
the maximum washing time. Please check the boiler safety clicson functioning and the
resistance.