1: Make sure that the valves on your heat pump are set correctly: By Pass: open to 50%, inlet valve: open to 100%,
outlet valve: open to 70%.
2: Turn on your filtration pump and check that there are no leaks in the hydraulic circuit and that the water is
circulating properly through the pool or spa's discharge nozzles.
3: Connect the power supply and then press the ON/OFF button on the remote control. If the installation is correctly
done, the heat pump should turn on immediately.
4: After a few minutes, the air released by the fan should be significantly cooler than the ambient air.
5: When the heat pump is running, turn off the filter pump and the unit should stop.
6: Run your filtration pump and heat pump 24 hours a day until the desired temperature is reached. When the
desired temperature is reached the unit will slow down, when the temperature is maintained for 45 minutes and ; the
unit will stop and restart automatically as soon as the water temperature is 0.2 °C lower than the set temperature
requested (Attention : your filtration pump must be running for the heat pump to work).