1. Introduction
The Three-phase control unit CT INVERTER AM three-phase is a device suitable for operating and controlling the sliding gate in a way easy and
complete; it is designed in order to satisfy all possible needs.
The inverter on board allows to set the maximum torque limits along with the possibility to modify the frequency (the speed of the motor).
The possibility to use motors with encoder allows the unit to detect possible obstacles along the run and reverse its direction of motion. It is suitable to
command and control automatics accesses equipped with three-phase motors 230/400Vac delta-connected max 1,5KW (current limited to 10A). Every
control board is equipped with a memory module that stores all personal settings and parameters needed for operating the control board (these data
can be transferred from one unit to another one). It is equipped with inputs for self-tested photocells, keys for SS (step-by-step), PED (partial opening),
OPEN and CLOSE, switch limits, security stops and a wide display with 3 keys for settings. It is also equipped with a molex connector for a plug-in
receiver, output for courtesy and flashing light. It is possible to connect an additional card (R1) to operate an electric lock.
WARNING: DO NOT INSTALL THE CONTROL UNIT WITHOUT READING THE INSTRUCTIONS FIRST!
For the connection of the motor we recommend to use a screened cables 3 poles + earth 1.5 mm
For the connection of the possible encoder we recommend to use a screened cable 3 x 0,75mm
NOTE: All unused NC inputs must be jumpered with the common.
In case an encoder is applied, it is compulsory to use a shielded cable with the screening connected to the EARTH
WARNING!! DELTA CONNECTION OF THE MOTOR IS REQUIRED.
6-1622596
rev.07
24/11/2022
It is FUNDAMENTAL to connect the motor and the unit
to the EARTH in order to operate the control unit correctly!
only by one end of the cable itself.
ITA
ENG
2
(type FD781CY)
2
(type OLFLEX-110CH)
FRA
ESP
DEU
POR
ANTENNA
Antenna
COM
Common
S.S.
Step by Step
PHOTO
Photocell
STOP
Stop
EDGE
Safety edge
L.S.CL.
Closing limit switch
L.S.OP.
Opening limit switch
PED.
Partial opening
OPEN
Opening command
CLOSE
Closing command
ENCODER
Encoder
SIG.
Encoder signal
GND
Ground
PHOTO POWER
Photocells power
SUPPLY
supply
+RX
Photo Receiver
+TX
Photo transmitter
W
V
Motor connections
U
PE
Terra
N
Neutro
Power supply
L
Fase
SYSTEM MEMORY
System memory
BLINKER
Flashing light
COURTESY LIGHT
Courtesy light
ELECRTIC LOCK
Electric lock ro brake
CARD CONNECTOR
card connector
RADIO RECEIVER
Radio receiver
FUSE
Fuse
INPUT LEDS
Input leds
POWER ON LEDS
Power on leds
2 / 12