Avoid putting the connection cables of buttons, security devices and inputs close to those of the power supply of the control unit and of the motor. Some
parts of the control unit are subject to dangerous voltage. The control unit must be installed and programmed only by qualified professionals. Always use
a device that ensures the disconnection of all poles of the control unit's power supply .
This device can be a switch (connected directly to the power supply terminals) with a contact's minimum distance of 3 mm for each pole, or it can be a
device connected to the power network.
For connecting the card and the motors we recommend to use cables with double isolation as in compliance to the laws in force; the minimum cross
section of the single conductor must not be less than 1,5 mm² and not more than 2.5mm².
TECHNICAL FEATURES - CT INVERTER AM THREE-PHASE
Power supply
Photocells power supply
Accessories power supply
Motor output
Flashing light output
Courtesy light output
Auxiliary output (only with card R1). Clean contact out-
put NOT supplied.
GUARANTEE - In compliance with legislation, the manufacturer's guarantee is valid from the date stamped on the product and is restricted to the re-
pair or free replacement of the parts accepted by the manufacturer as being defective due to poor quality materials or manufacturing defects. The
guarantee does not cover damage or defects caused by external agents, faulty maintenance, overloading, natural wear and tear, choice of incorrect
product, assembly errors, or any other cause not imputable to the manufacturer. Products that have been misused will not be guaranteed or repaired.
Printed specifications are only indicative. The manufacturer does not accept any responsibility for range reductions or malfunctions caused by environ-
mental interference. The manufacturer's responsibility for damage caused to persons resulting from accidents of any nature caused by our defective
products, are only those responsibilities that come under Italian law.
6-1622596
rev.07
24/11/2022
WARNING AND ADVICES
230 Vac +15%, -15% ; 50Hz single-phase
24 Vdc 3W MAX
24Vac 3W MAX
230Vac Three-phase 1,5KW (current limited to 10A) MAX cosΦ > 0.8
230 Vac 60W MAX for fixed light, without self-blinking.
230Vac 100W MAX
24Vac 0.5A MAX (12W MAX)
ALLMATIC S.r.l
32026 Borgo Valbelluna - Belluno – Italy
Via dell'Artigiano, n°1 – Z.A.
Tel. 0437 751175 – 751163 r.a.
http://www.allmatic.com - E-mail: info@allmatic.com
ITA
ENG
Fax 0437 751065
FRA
ESP
DEU
POR
12 / 12

Publicidad

loading

Este manual también es adecuado para:

Cst am02