1
Torch attachment
Allows the connection of the torch.
2
External devices
Allows the external devices to be connected and
checked.
3
Compressed air 1
Allows the connection of the compressed air pipe.
4
Cooling liquid
Allows the connection of the pipes of a water-cooled
torch.
3.4 Rear panel
Right version
Left version
1
Signal cable input (CABLE BUNDLE)
2
Gas fitting
3
Compressed air fitting
4
Wire input
5
Cooling liquid inlet/outlet
4 ACCESSORIES
4.1 Push-Pull kit (73.11.018)
"Consult the "Installation kit/accessories" section".
4.2 Wire-End/Speed meter connection kit
(73.11.026)
(Factory assembly).
4.3 Wire-End sensor kit (73.50.080)
(Factory assembly).
5 MAINTENANCE
Routine maintenance must be carried out on the
system according to the manufacturer's instruc-
tions.
Any maintenance operation must be performed by qualified
personnel only.
When the equipment is working, all the access and operating
doors and covers must be closed and locked.
Unauthorized changes to the system are strictly forbidden.
Disconnect the power supply before every opera-
tion!
Carry out the following periodic checks on the
power source:
- Check the electric connections and all the con-
nection cables.
For the maintenance or replacement of torch components,
electrode holders and/or earth cables:
Check the temperature of the component and
make sure that they are not overheated.
Always use gloves in compliance with the safety
standards.
Use suitable wrenches and tools.
Failure to carry out the above maintenance will invalidate all
warranties and exempt the manufacturer from any liability.
6 TROUBLESHOOTING
The repair or replacement of any parts in the
system must be carried out only by qualified
personnel.
The repair or replacement of any parts in the system by unau-
thorised personnel will invalidate the product warranty.
The system must not be modified in any way.
The manufacturer disclaims any responsibility if the user
fails to follow these instructions.
The system fails to come on (green LED off)
Cause
No mains voltage at the socket.
Solution
Check and repair the electrical system as needed.
Use qualified personnel only.
Cause
Faulty plug or cable.
Solution
Replace the faulty component.
Contact the nearest service centre to have the sys-
tem repaired.
Cause
Line fuse blown.
Solution
Replace the faulty component.
27