Troubleshooting
Often, failures have simple causes and you
can do the troubleshooting yourself using
the following overview. If you are in doubt
or if the failure is not listed here please con-
tact the authorized customer service.
Danger
Always disconnect the mains plug and al-
low the steam cleaner to cool down before
performing any maintenance work.
Repair works may only be performed by the
authorized customer service.
Long heating-up time
Steam boiler is decalcified
Descale the steam boiler.
No steam
No water in the steam boiler.
Turn off the appliance.
See „Refilling Water" Page 9.
Steam lever cannot be pressed anymore
Steam switch is secured with the lock /
child-proof lock.
Push the steam switch lock to the back.
Steam chamber too full
Press the steam gun until less water is
).
emitted.
Steam boiler is decalcified
Descale the steam boiler.
Technical specifications
Power connection
Voltage
Protective class
Protection class
Performance data
Heating output
Operating pressure max.
Heating time
per litre of water
Steam volume
Continuous steaming
Steam push max.
Dimensions
Boiler capacity
Weight (without acces-
sories)
Width
Length
Height
Subject to technical modifications!
EN
– 12
High water output
220-240
1~50/60
V
Hz
I
IPX4
1500 W
0,32 MPa
8 Min-
utes
40 g/min
100 g/min
1,0 l
3,4 kg
250 mm
381 mm
260 mm
21