OPERATION
Place Air Mover in desired operating position (Your Unit May Not Be As Illustrated):
FLOOR & CARPET (Fig. 2)
Foot Bumpers (4)
90° CEILINGS & VENTILATION (Fig. 3)
SP7019-2 AIRMOVER ESF.indb 5
SP7019-2 AIRMOVER ESF.indb 5
45° WALLS & VENTILATION (Fig. 4)
Fig. 2
AIR MOVER INTERCONNECTION
RIDGID Air Movers can be interconnected in series
using the convenience outlets. Applicable Models
include AM22871 and AM22881. If utilizing the series
interconnection feature, only use Air Movers that
total less than the recommended 7.9 Amp maximum
Fig. 3
convenience outlet rating. The 8 Amp on-board circuit
breaker will allow up to two (2) additional RIDGID
Air Movers to run on the first Air Mover at the same
time.
NOTE: Air Mover Models AM22871 and AM22881 are
equipped with convenience outlets with an on-board
8 Amp circuit breaker. If the convenience outlet
overloads, the circuit breaker will trip. If the circuit
breaker does trip, turn the switch to the off position
and unplug all units then press the circuit breaker reset
button. Plug the units back into the power source.
The on-board convenience outlets on the Air Mover will
be actively powered when the Air Mover is plugged in
and the circuit breaker is properly reset.
5
Fig. 4