EN
TESTING GRAINS THAT ARE ABOVE OR BELOW THE LIMITS
If the grain being tested in the tester is above or below the grains calibration limits
the tester will display a < (less than) or > (greater than) symbol followed by the tested
grain's upper or lower moisture limit.
DISPLAYING THE AVERAGED MOISTURE RESULTS
1.
Each time a moisture test is taken the averaged moisture result is automatically
displayed along with the current moisture and temperature.
2.
The averaged results are stored for each individual grain, so when switching
between grains there is no need to clear the averaging results as the tester
calculates the average for each grain individually.
3.
The tester by default will display the averaged results of the last selected number
of tests performed on the tested grain. (The default is the average of the last 3
tests)
FUNCTIONS AND SETTINGS
Settings can be checked and changed in options menu.Navigate to options in grain
menu with arrow buttons and select with enter button. Following settings are found in
options menu.
GRAIN OFFSET /CALIBRATION
Each grain can be individually adjusted by 5 % in increments of 0.1% to match the
results of an elevator tester.
Choose grain with right side arrow button. Adjust the offset with up/down buttons.
Save offset with enter button.
MT PRO PLUS manual_short version_SE_Agratronix.indd 51