6.5
Press and hold SET, it displays "P1".
6.5.1
Press UP once, it displays"P2",
6.5.2
Press SET once again, it will show the current situation. Press UP to increase
the force one degree or press DOWN to decrease one degree. Maximum
6.5.3
degree is "F9", minimum is "F1".
Press SET to confirm. The default setting is "F5".
6.5.4
6.5.5
After finishing all the setting, please check the force to make safe.
6.6
6.6.1
Press and hold SET, it displays " P1" .
Press UP twice, it displays "P3".
6.6.2
Press SET to show current situation. Press UP once it displays "H1", the
photo beam is enabled. Press down once, It displays "H0", the
6.6.3
photo beam is disabled. Press SET to confirm and quit.
If you do not use photo beam device, please make sure it
6.6.4
displays" H0," to close this function.
6.7
Press and hold SET, it displays "P1".
6.7.1
Press UP three times, it displays "P4".
6.7.2
Press SET to show current situation. Press UP to increase the auto-close
one minute or press DOWN to decrease one minute. Maximum degree
6.7.3
is "b9" , minimum is "b0". Press SET to confirm.
The default setting is " b0", " b0" shows auto-close off.
6.7.4
function works when the door reaches the open position.
6.8
Press and hold SET, it displays "P1".
6.8.1
Press UP four times, it displays "P5 ".
6.8.2
Press SET to show current situation. Press UP, it displays "Lc ", lock door
function works or press DOWN, It displays "uL", lock door function doesn't
6.8.3
work. Press SET to confirm the function you need.
When you use uncovered transmitters,it is recommended using lock
6.8.4
door function. This function works when the door reaches the closed position,
you can't open the door until press the" unlock"button first.
Force Adjustments
Photo Beam
Auto-Close ON/OFF
Lock Door
10
00
DS
RE
SA
his
T