Problems/Causes /Solutions
In the event of any problems with the use of the motor pump, refer to the table below. If it is not possible to remedy
the problem, contact one of the Sibrape resellers.
Problem
Motor does not receive electricity;
Pump won't
Burned fuses; incorrect electrical
start
Motor won't
reach rated
speed
Motor heating
Pump works
but won't pump
Insufficient
flow and
pressure
Excessive noise
or vibration
10
Installation and User's Guide
Cause
General electric switch off;
connections;
Low current;
Low current;
Incorrect electric connection;
Low tension;
Incorrect connection;
Pump is not primed;
Closed valves;
Air intake in the suction pipe;
Incorrect direction of rotation;
Incorrect impeller rotation;
Partially closed records;
Pre-filter basket saturated;
Air in the pipeline;
Low speed motor;
Inverted direction of rotation;
Pre-saturated filter basket;
Partially closed records;
Clogged pipes;
Solution
Check the circuit and correct; Turn on
the main switch; Replace the electric
fuses;
Correct the electrical connections;
Check the circuit and correct
Check the circuit and correct;
Correct the electric connection;
Check the circuit and correct;
Correct the connection;
Prime the pump; Open the valves;
Eliminate the air intake;
Correct the motor rotation direction;
Correct the impeller rotation;
Open the records;
Clean the basket;
Repair the pipe;
Check the connections and correct;
Correct the engine speed;
Clean the basket;
Open the records;
Clean the pipe;