Zone settings
Press on the icons to access the parameters:
Sleep mode. Sleep mode is an eco-timer for switching off the zone. The selectable values
are:
Off. The timer is off.
30. Activates the timer and after 30 minutes, the zone is switched off.
60. Activates the timer. After 30 minutes, the zone changes its temperature by one
degree and 60 minutes after activation, the zone switches off.
90. Activates the timer. After 30 minutes, the zone changes its temperature by one
degree. 60 minutes after activation, the zone changes its temperature by another
degree. 90 minutes after activation, the zone switches off.
Anti-freezing. Prevents the room temperature in the zone from dropping below 12°C, even
if the zone is off. (In Stop mode it will not be activated).
Lite settings. In this parameter, you can define the base set-point temperature for the
zone where the Airzone Lite thermostat is installed. You can also configure the wired Lite
thermostat to act as a wireless thermostat: after a few seconds (during which it indicates
the status of the zone), it will switch off.
Note: To access the Lite settings parameter, from any Airzone Blueface zero thermostat you
must access the zone controlled by your Lite thermostat using the Zone navigation option.
Depending on your installation and the configuration of your system, you can manage the
following parameters:
Grille angle. Allows you to define an inclination on the Airzone smart grilles in the zone for
cooling and heating modes. The options are 40°, 45°, 50° and 90° (90° by default).
Control stages. Allows you to select the element you wish to heat or cool the zone.
Air. Only the air stage works.
Radiant. Only the radiant stage works.
Combined. The system combines the use of the air and radiant stages to reach the
comfort temperature quickly and efficiently. This is the default setting.
Adjust slats. Define the inclination type of the horizontal and vertical slats on the systems
where this function is available.
Q-Adapt. Allows you to define the airflow control algorithm that best fits the duct
installation. The options available are:
Maximum: the system operates at maximum speed regardless of the number of zones.
Power: the system operates at a higher speed than in Standard mode to ensure airflow is
increased.
Standard: the system changes speed depending on the number of zones.
Silence: the system operates at a lower speed than in Standard mode to improve noise
reduction.
Minimum: the system operates at minimum speed regardless of the number of zones.
Note: In case of having a 0-10 V gateway; the algorithm, in addition, will take into account the
minimum and maximum voltage values set by your installer in this menu.