X-LINE SOURCES AND CHARGERS - INSTRUCTION MANUAL
DASHBOARD FROM CONTROL
8. LED that indicates the voltage parameter VOLTAGE, CURRENT
or BATTERY CHECK-UP (2 LEDS on);
9. VOLTAGE, CURRENT and BATTERY CHECK-UP readings selector key;
10. Selector switch of SLOW LOAD, AUTO SCI e OUTPUT VOLTAGE;
11. LEDs that indicate SLOW LOAD, AUTO SCI and OUTPUT VOLTAGE;
12. BATTERY capacity selector switch (when in SLOW CHARGE mode), VOLTAGE of the output (when
in VOLTAGE OUTPUT mode) or triggering of the X-LINE function (press for 2 seconds);
13. BATTERY CHARGED LED indicator;
14. Indicator LEDs of the 3 loading phases of SLOW LOAD mode;
15. Voltage/current indicator display or hour ampere counter.
INSTALLATION AND CONNECTIONS
X-LINE sources have a robust fixation system, allowing them to be firmly fixed by the
metal chassis, giving greater resistance and safety in the installation (fig. 1).
To remove the protective cover from the DC connectors, pull it up by exposing the
connecting screws to the output cables (fig. 2).
Fig. 1
8
CONTROL PANEL
PAINEL DE CONTROLE
BATTERY CHECK-UP
CHECK-UP DA BATERIA
VOLTAGE
AMPERAGE
TENSÃO
CORRENTE
READING
SELETOR
9
LEITURA
SELECTOR
MEDIDOR
CCA - Ri m
CCA - Ri m
METER
10
SELETOR
MODE
MODO
SELECTOR
SELETOR
SELECTOR
CARGA
AUTO
TENSÃO
BATERIA
SLOW
AUTO
OUTPUT
BATTERY
LENTA
SCI
SAÍDA
s u p e r - x
CHARGE
ICS
VOLTAGE
11
SLOW CHARGE
15
CARGA LENTA
PHASES
1. ELEVAÇÃO
1.ELEVATION
2. ABSORÇÃO
2.ABSORPTION
3. EQUALIZAÇÃO
3.EQUALIZATION
12
13
TENSÃO
BATERIA
VOLTAGE
CHARGED
CARREGADA
BATTERY
Fig. 2
14
4