ATTENTION!
The following mounting instructions
must be observed!
Before installation, compare
the mains voltage / frequency
specifications on the type plate with
those of the local mains.
The changeover time for changing
the running direction must be at
least 0.5 seconds!
The switches or controls used must
not execute a simultaneous UP/
DOWN command!
Moving parts of motors that are
operated below a height of 2.5
m above the ground must be
protected.
The winding shaft must be mounted
horizontally! If the hangings are
wound up at an angle, the motor or
the hangings may be damaged.
Inspection openings must be easily
removable and accessible and must
not be permanently closed off
inaccessibly.
IMPORTANT!
For permanently installed devices, a
disconnecting device for each phase
must be provided on the part of the
installation in accordance with DIN
VDE 0700.
Switches with a contact opening
width of at least 3 mm (e.g. circuit
breakers, fuses or RCDs) are
considered to be disconnecting
devices.
The manufacturer's liability for
defects and damage is excluded if
these are due to non-observance
of the assembly and operating
instructions (incorrect installation,
incorrect operation, etc.).
GENERAL SAFETY INSTRUCTIONS
IMPORTANT!
Disposal instructions!
European Directive 2012/19/EU (WEEE)
Our electrical and
electronic products
are marked with a
crossed-out wheeled
garbage can, which
indicates that these
products and any bat-
teries they may cont-
ain must be collected
separately at the end
of their service life and
not be disposed of with other house-
hold waste.
19