INSTALLATION & PREPARATION
NOZZLE CONNECTION:
1. Be certain the trigger gun is locked in the "OFF" position. See WARNING,
right.
2. The nozzle assembly should be disconnected from the gun/wand assembly
at this by retracting the locking ring on the quick-connect fitting to remove
the nozzle.
WATER SUPPLY:
1. Select a water supply hose which is a quality grade of garden hose measuring
at least 3/4" ID and no longer than 50 feet.
2
Check the water inlet strainer to ensure it is clean and free of any obstructions.
Periodic cleaning of the water strainer will help prevent pump problems.
As a strainer becomes obstructed, it restricts proper flow of water to the
pump. This can cause cavitation which will result in premature failure of
pump packings and valves. Using a screw driver, remove the screen; clean
or replace if necessary.
3. Connect the hoses.
a. Connect one end of the water supply hose to the water inlet of the unit.
b. Connect the other end of the hose to your pressurized water supply.
NOTE: Do not use a non-pressurized water supply (i.e. from a well or
pond) with this unit.
c. Connect the high pressure discharge hose to the water outlet of the
unit.
4. Follow the incoming water requirements listed below:
a. Water pressure must be a minimum of 20 pounds per square inch (PSI)
and a maximum of 125 PSI. (A typical outdoor faucet will generally
supply this PSI if turned completely "ON".)
b. Incoming GPM must be approximately one gallon more than the outgoing
GPM stated on the pressure washer nameplate. (You can check GPM
by timing how long it takes to fill a 5 gallon container.
c. Incoming water temperature must not exceed 140°F (78°C). Excessive
pump damage may result if the water temperature exceeds this
acceptable level.
5. Never allow the unit to operate without the incoming water line attached
and the water supply turned all the way on.
UNLOADER:
The unloader valve on your machine is equipped with an adjustment knob
to adjust the pressure. Should less pressure be required, simply turn the ad-
justment knob counterclockwise. To set back to maximum, turn adjustment
knob completely clockwise. DO NOT OVERTIGHTEN!
CA Electric Operator's Manual
QUICK-CONNECT FITTING
WARNING: RISK OF SEVERE
INJURY!
THE TRIGGER GUN SHOULD ALWAYS BE
LOCKED IN THE OFF POSITION WHEN NOT
IN USE!
CHECK WATER INLET STRAINER
CAUTION: RISK OF UNIT DAMAGE!
DO NOT OVERTIGHTEN THE UNLOADER.
BREAKAGE WILL RESULT IN IMMEDIATE
LOSS OF WATER PRESSURE AND COSTLY
REPAIRS.